R88M-W75030T-BS1 Omron, R88M-W75030T-BS1 Datasheet - Page 267
R88M-W75030T-BS1
Manufacturer Part Number
R88M-W75030T-BS1
Description
SERVO MOTOR 750W 200V W/BRAKE
Manufacturer
Omron
Datasheet
1.R88A-TK05W.pdf
(412 pages)
Specifications of R88M-W75030T-BS1
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88MW75030TBS1
- Current page: 267 of 412
- Download datasheet (7Mb)
Operation
• This parameter sets the switching speed for the step 1 and step 2 deceleration when two-step
• Sets the bias for when an exponential filter is used for the position command filter.
• This parameter sets the time constant for when an exponential filter is used for the position com-
• Sets the average movement time for when and an average movement filter is used for the position
• If the Servo Driver is used with the CJ1W-MCH71 or CS1W-MCH71, this parameter will be set to
Note Do not change setting.
• Sets the distance from the external signal input position when external positioning is executed. For
●
Pn80F
Setting
range
Pn810
Setting
range
Pn811
Setting
range
Pn812
Setting
range
Pn813
Setting
range
Pn814
Setting
range
Pn816.0
Setting
range
deceleration is executed. When using one-step acceleration, set the deceleration parameter switch-
ing speed (Pn80F) to 0.
mand filter.
command filter. Set when using S-curve acceleration/deceleration.
0032.
If parameters are edited with the WMON-ML2 connected, this parameter will set to 0000.
If this happens, you must reset this parameter to 0032 from the CJ1W-MCH71 or CS1W-MCH71.
a negative direction or if the distance is short, operation is reversed after decelerating to a stop.
Origin Search Parameters (Pn816 to Pn819)
Deceleration parameter switching speed (Position)
0 to 65535
Exponential acceleration/deceleration bias (Position)
0 to 32767
Exponential acceleration/deceleration time constant (Position)
0 to 5100
Moving average time (Position)
0 to 5100
Not used.
---
Final travel distance for external positioning (Position)
− 1073741823
to
1073741823
Zero point return mode settings -- Zero point return direction (Position)
0, 1
Unit
Unit
Unit
Unit
Unit
Unit
Unit
× 100 Com-
mand unit/s
Command
unit/s
× 0.1 ms
× 0.1 ms
---
Command
unit
---
Default
setting
Default
setting
Default
setting
Default
setting
Default
setting
Default
setting
Default
setting
0
0
0
0
0
100
0
Restart
power?
Restart
power?
Restart
power?
Restart
power?
Restart
power?
Restart
power?
Restart
power?
Chapter 4
No
No
No
No
No
No
No
4-71
Related parts for R88M-W75030T-BS1
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: