DZ-10GW22-1A Omron, DZ-10GW22-1A Datasheet - Page 2

Basic / Snap Action / Limit Switches BASIC SWITCH

DZ-10GW22-1A

Manufacturer Part Number
DZ-10GW22-1A
Description
Basic / Snap Action / Limit Switches BASIC SWITCH
Manufacturer
Omron
Series
DZr
Datasheet

Specifications of DZ-10GW22-1A

Actuator
Roller Lever
Operating Force
400 g
Contact Form
DPDT
Contact Rating
10 Amps at 250 Volts
Termination Style
Solder
Mounting
Panel
Lead Free Status / Rohs Status
 Details
Specifications
■ Ratings
Note: 1. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
■ Characteristics
Note: 1. The values are for pin plunger models. (Contact your OMRON representative for other models.)
■ Approved Standards
UL508 (File No. E41515)/CSA C22.2 No. 55 (File No. LR21642)
DZ-10G: 10 A, 125 VAC
2
125 VAC
250 VAC
8 VDC
14 VDC
30 VDC
125 VAC
250 VDC
Operating speed
Operating frequency
Insulation resistance
Contact resistance
Dielectric strength
Vibration resistance
Shock resistance
Life expectancy
Ambient temperature
Ambient humidity
Weight
voltage
Rated
2. Lamp load has an inrush current of 10 times the steady-state current.
3. Motor load has an inrush current of 6 times the steady-state current.
2. Malfunction: 1 ms max.
10 A, 250 VAC
2 A, 480 VAC
1/2 A, 125 VDC
1/4 A, 250 VDC
1/8 HP 125 VAC
1/4 HP 250 VAC
Special-purpose Basic Switch
10 A
10 A
10 A
10 A
10 A
0.5 A
0.25 A
NC
Resistive load
0.1 mm to 1 m/s (at pin plunger)
Mechanical: 240 operations/min
Electrical:
100 MΩ min. (at 500 VDC)
15 mΩ max. (initial value)
1,000 VAC, 50/60 Hz for 1 min between non-continuous terminals
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal part, and be-
tween current-carrying metal part and ground and between switches
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Destruction: 1,000 m/s
Malfunction: 300 m/s
Mechanical: 1,000,000 operations min.
Electrical:
Operating:
Operating:
Approx. 30 to 50 g
Non-inductive load
NO
2 A
1.5 A
3 A
3 A
3 A
0.5 A
0.25 A
20 operations/min
50,000 operations min.
-25° C to 80° C (with no icing)
35% to 85% max.
NC
Lamp load
DZ
2
{approx. 30G} max. (see notes 1 and 2.)
2
1 A
0.7 A
1.5 A
1.5 A
1.5 A
{approx. 100G} max.
NO
6 A
4 A
6 A
6 A
4 A
0.05 A
0.03 A
NC
Inductive load
■ Contact Form
NO
Inductive load
3 A
2 A
5 A
5 A
3 A
0.05 A
0.03 A
NC
Motor load
COM1
COM2
1.5 A
1 A
2.5 A
2.5 A
1.5 A
NO
NC1
NO1
NC2
NO2
30 A max.
NC
Inrush current
15 A max.
NO

Related parts for DZ-10GW22-1A