NS7-KBA05 Omron, NS7-KBA05 Datasheet - Page 98

no-image

NS7-KBA05

Manufacturer Part Number
NS7-KBA05
Description
PROTECTIVE PLASTIC COVER FOR NS7
Manufacturer
Omron
Datasheet

Specifications of NS7-KBA05

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
NS7KBA05
3-8 Installing the Controller Link Interface Unit
3-8-2
3-44
Nomenclature and Functions
Familiarize yourself with the nomenclature and functions of the Controller Link Support
Board before operation.
Reference
Communications Connector
Connects to Controller Link Network
communications cable using the cable
connector provided
Card Edge Connector
Connects to the connector of
the Connector Conversion
Board.
Plate
Attaches to the cover.
To identify nonconforming Controller Link Boards, check the Model printed on the Plate.
This will tell you whether it conforms with EC Directives.
Model 3G8F5-CLK21: Does not conform with EC Directives
Model NS-CLK01: Conforms with EC Directives
.
Terminating Resistance Switch
This is a slide switch. Turn ON the
terminating resistance if the Board is
at the end node in a Controller Link
Network. The switch must be set to
OFF at other nodes.
Interrupt shorting Pin
Set at the factory. Do not
change the factory setting.
Memory Allocation Switch
Set at the factory. Do not change
the factory setting.
Indicators
Display the status of the