NS7-KBA05 Omron, NS7-KBA05 Datasheet - Page 203
NS7-KBA05
Manufacturer Part Number
NS7-KBA05
Description
PROTECTIVE PLASTIC COVER FOR NS7
Manufacturer
Omron
Datasheet
1.NS12-TS01B-V2.pdf
(334 pages)
Specifications of NS7-KBA05
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
NS7KBA05
- Current page: 203 of 334
- Download datasheet (7Mb)
6-3-9
6-3-10 Changing Values in Device Monitor Setting
6-3-11 Contrast (NS5-SQ@@/NS5-MQ@@ Only)
Orientation
If the printer control method is set to ESC/P raster or BJ raster, select the printing orientation
of the printer that will be connected to the NS-series PT.
1. Select either Portrait or Landscape in Orientation.
2. After setting, press the Write Button to save the setting.
This setting enables using the registered monitor and switch box functions of the device
monitor only for monitoring by prohibiting address changes while monitoring.
Disable Button: Prohibits changing monitor values
Enable Button: Enables changing monitor values (factory default)
This setting can also be made with the CX-Designer on the PT Operation Tab Page of the
System Settings.
This function adjusts the screen contrast. Contrast can be adjusted in 100 degrees.
Adjust the contrast by using operations from the PT Tab Page in the System Menu, as fol-
lows:
1. Select Color Print, Monochrome Print, or Monochrome Print (Inverse) in Print Type.
2. After setting, press the Write Button to save the setting.
Portrait: Prints with the longer page measurement as the height (factory default).
Landscape: Prints with the shorter page measurement as the height.
6-3 PT Settings
6-29