R88A-CAWB015S Omron, R88A-CAWB015S Datasheet - Page 47

no-image

R88A-CAWB015S

Manufacturer Part Number
R88A-CAWB015S
Description
POWER CABLE 15M
Manufacturer
Omron
Datasheet

Specifications of R88A-CAWB015S

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88ACAWB015S
G3JA
3-Phase Hybrid Soft Starters Extend
Motor Life
• G3JA-D Current Limit Starter for 3-phase, 6-lead motors
• G3JA-C Soft Start, Kick Start, Current Limit Start, and Soft
• Smooth motor starts and stops can reduce mechanical
• Reduced power loss through hybrid control: Power supplied
• Slim 45-mm body saves installation space; all models have
Soft Starters Ordering Information
Current Limit Starters
For complete specifications and additional models:
100 to
240 VAC,
50/60 Hz
voltage
provides internal Star-delta control and simplifies wiring.
Star-delta and protective functions are included in this single
unit
Stop functions for 3-phase inductive motors satisfy motor
performance needs for a wide range of applications. Internal
protections include protection against overload and phase
loss
shock, leading to longer motor life, less frequent servicing
and lower maintenance costs
through a thyristor during starting or stopping and through a
bypass relay during stable operation
the same shape
Supply
Soft Starters
G3JA
Soft Starters
3
9
16
20
25
32
51
64
Main circuit operating
Current
rating
current (A)
1 to 3
3 to 9
5.3 to 16
6.7 to 20
9.2 to 27.7
10.9 to 32.9
17.3 to 51.9
21.3 to 64
Adjustable
range
0.2 to 0.4
0.55 to 1.5
1.1 to 2.2
1.5 to 3.7
2.2 to 5.5
3.7 to 7.5
5.5 to 11
5.5 to 15
200 VAC 50/
60 Hz
0.55
2.2
4
5.5
5.5
7.5
15
18.5
Lamp load (kW)
230 VAC
50 Hz
U.S. www.omron.com/oei Canada www.omron.ca
1.1
4
7.5
7.5
11
15
22
30
380/400/415 VAC
50 Hz
• Electronic Thermal Overload Relay built in protects the
• Optional Auxiliary Contact Block enhances operation
• Meets UL508; cULus listed; complies with IEC standards,
motor from problems such as burning due to motor
overload or locking. The overload class can be set to OFF,
10, 15, or 20
monitoring by providing an output of operating status
etc.
0.5
0.75 to 2
1.5 to 3
2 to 5
3 to 7.5
3 to 10
5 to 15
7.5 to 20
200 VAC
60 Hz
0.5
0.75 to 2
1.5 to 5
2 to 5
3 to 7.5
5 to 10
7.5 to 15
7.5 to 20
230 VAC
60 Hz
HP
0.5 to 1.5
1.5 to 5
5 to 10
5 to 10
7.5 to 15
7.5 to 20
15 to 30
20 to 40
460 VAC
60 Hz
R002
G3JA-D403B
AC100-240
G3JA-D409B
AC100-240
G3JA-D416B
AC100-240
G3JA-D420B
AC100-240
G3JA-D425B
AC100-240
G3JA-D432B
AC100-240
G3JA-D451B
AC100-240
G3JA-D464B
AC100-240
Model
I-39