R88A-CAWB015S Omron, R88A-CAWB015S Datasheet - Page 29

no-image

R88A-CAWB015S

Manufacturer Part Number
R88A-CAWB015S
Description
POWER CABLE 15M
Manufacturer
Omron
Datasheet

Specifications of R88A-CAWB015S

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88ACAWB015S
3G3JV
Specifications
3G3JV Inverter Ordering Information
Manuals
For complete specifications and additional models:
Cooling fan fault
Stall prevention
Ground fault
Power charge indication
Environmental conditions
Enclosure rating
Location
Ambient temperature
Storage temperature
Humidity
Elevation
Wiring distance
Vibration
Other functions
Multi-function inputs
Multi-function outputs
Standard functions
Compact inverter
with V/Hz control
User’s manual
Description
Item
Inverters
NEMA 1
Open chassis
Enclosure
3G3JV User’s manual
(Continued)
Protected by electronic circuit (fan-stalling detection)
Individual levels during acceleration/running, enable/disable provided during deceleration
Protected by electronic circuit (rated output current level)
RUN lamp stays ON or digital operator LED stays ON. (Charge LED is provided for 460 V) ON until the DC bus
voltage becomes 50 V or less
Open chassis: IP20
Indoor (free from corrosive gases and dust)
Open chassis: 14 to 122°F (-10 to +50°C), not frozen
-4 to 140°F (-20 to 60°C)
95% RH (Non-condensing)
1,000 m (3,281 feet) or below
328 ft (100 m) or less between inverter and motor
9.8 m/s
Four of the following input signals are selectable: Reverse run (3-wire sequence), fault reset, external fault
(NO/NC contact input), multi-step speed operation, Jog command, accel/decel time select, external baseblock
(NO/NC contact input), speed search command, accel/decel hold command, LOCAL/REMOTE selection,
communication/control circuit terminal selection, emergency stop fault, emergency stop alarm.
Following output signals are selectable (1 NO/NC contact output): Fault, running, zero speed, at frequency,
frequency detection (output frequency = or = set value), during overtorque detection, minor error, during
baseblock, operation mode, inverter run ready, during fault retry, during under-voltage, during speed search,
data output through communication.
Full-range automatic torque boost, slip compensation, DC injection braking current/time at start/stop frequency
reference bias/gain, frequency reference with built-in potentiometer, MEMOBUS communications (RS-485/422,
max. 19.2 K bps) capable with optional unit.
1
2
1
2
3
5
1/2
1
2
3
3
5
1/8
1/4
3/4
1/8
1/4
3/4
2
(1G) less than 20 Hz, up to 1.96 m/s
HP
240
240
240
240
240
230
230
230
230
230
230
230
460
460
460
460
460
460
Rating
U.S. www.omron.com/oei Canada www.omron.ca
Voltage
Description
1
1
1
1
1
3
3
3
3
3
3
3
3
3
3
3
3
3
Phase
2
(0.2G) at 20 to 50 Hz
3G3JV-AB001-A
3G3JV-AB002-A
3G3JV-AB004-A
3G3JV-AB007-A
3G3JV-AB015-A
3G3JV-A2001-A
3G3JV-A2002-A
3G3JV-A2004-A
3G3JV-A2007-A
3G3JV-A2015-A
3G3JV-A2022-A
3G3JV-A2037-A
3G3JV-A4002-A
3G3JV-A4004-A
3G3JV-A4007-A
3G3JV-A4015-A
3G3JV-A4022-A
3G3JV-A4037-A
Model
I528-E3-1
Model
I-21