Specifications of R88A-CCW002C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88ACCW002C
Standard Models and Specifications
Note 7. Use the Terminal Block only after allocating Servo Driver signals to pins. The following param-
I/O Signal (CN1) Parameter Settings
2-6-2 Motor Cable Specifications
The motor cable is used to connect the Servo Driver and Servomotor. Select the appropriate cable for
the Servomotor. The maximum distance between Servo Driver and Servomotor is 50 m.
Note Use a Robot Cable if the cable needs to bend.
D Bend Resistance of Robot Cables
Robot Cables use wire that has a bending life of 20 million times when used at the minimum bending
radius (R) or greater under the following conditions.
Note 1. The bending resistance data was compiled under test conditions and must be used as a guide
Note 2. The life expectancy is the number of uses without cracks or damage to the sheath that would
Note 3. If Robot Cables are used at a bending radius smaller than the minimum bending radius, me-
Pn50A
Pn50B
Pn511
Pn50F
Parameter No.
eters are set when wiring as described in the above wiring example.
only. An extra margin must always be allowed.
affect performance while current is applied to the wire conductor. This value does not apply to
cut shield strands.
chanical malfunctions, ground faults, and other problems may occur due to insulation break-
down. Contact your OMRON representative if you need to use a Robot Cable with a bending
radius smaller than the minimum bending radius.
Input Signal Selection 1
Input Signal Selection 2
Input Signal Selection 5
Output Signal Selection 2
Name
Input signal
Output signal
2881
8883
6541
0200
Setting
Chapter 2
2-131