R88A-TK01W Omron, R88A-TK01W Datasheet - Page 95

no-image

R88A-TK01W

Manufacturer Part Number
R88A-TK01W
Description
BRACKET R88D-WT20H/30H/50H
Manufacturer
Omron
Datasheet

Specifications of R88A-TK01W

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
R88ATK01W
Standard Models and Specifications
5. Servo Phase-B Selectors (Not Used)
Leave these selectors set to INC mode.
Screwless clamp terminal blocks enable wiring without securing the wires with screws. Special fer-
rules must be attached to the cables for sensors or external devices if sensors or external devices
are also to be connected when wiring the Servo Driver and the control signal.
The following ferrules are applicable.
Inserting a Wire
Fully insert the ferrule all the way into the desired terminal hole.
Releasing a Wire
Insert a small flathead screwdriver into the release button above the terminal hole, and pull out the
wire while pressing the button.
Phoenix Contact
Nihon Weidmuller
Servo #2 phase-B
selector servo2
Wiring Procedure
Manufacturer
Wiring to Screwless Clamp Terminal Blocks
ABS_CW-
INC
Release button
Servo #1 phase-B
selector servo1
ABS_CW-
INC
Small flathead screwdriver
AI-0.5-10
AI-0.75-10
AI-1.5-10
H 0.5/16 D
H 0.75/16 D
H 1.5/16 D
Model
0.5 mm
0.75 mm
1.25 mm
0.5 mm
0.75 mm
1.25 mm
Applicable wire
2
2
2
2
2
2
(20 AWG)
(20 AWG)
(18 AWG)
(16 AWG)
(18 AWG)
(16 AWG)
Chapter 2