PCA9674TS,112 NXP Semiconductors, PCA9674TS,112 Datasheet - Page 11

IC I/O EXPANDER I2C 8B 20SSOP

PCA9674TS,112

Manufacturer Part Number
PCA9674TS,112
Description
IC I/O EXPANDER I2C 8B 20SSOP
Manufacturer
NXP Semiconductors
Datasheet

Specifications of PCA9674TS,112

Interface
I²C
Number Of I /o
8
Interrupt Output
Yes
Frequency - Clock
1MHz
Voltage - Supply
2.3 V ~ 5.5 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
20-SSOP
Includes
POR
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
935283189112
PCA9674TS
PCA9674TS

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PCA9674TS,112
Manufacturer:
NXP/恩智浦
Quantity:
20 000
NXP Semiconductors
PCA9674_PCA9674A_5
Product data sheet
7.2.1 Software Reset
The Software Reset Call allows all the devices in the I
state value through a specific formatted I
implies that the I
The Software Reset sequence is defined as following:
The I
time) as a ‘Software Reset Abort’. The PCA9674/74A does not initiate a reset of its
registers.
The unique sequence that initiates a Software Reset is described in
1. A START command is sent by the I
2. The reserved General Call I
3. The PCA9674/74A device(s) acknowledge(s) after seeing the General Call address
4. Once the General Call address has been sent and acknowledged, the master sends
5. Once the right byte has been sent and correctly acknowledged, the master sends a
Fig 9.
Fig 10. Software Reset sequence
is sent by the I
‘0000 0000’ (00h) only. If the R/W bit is set to 1 (read), no acknowledge is returned to
the I
1 byte. The value of the byte must be equal to 06h.
a. The PCA9674/74A acknowledges this value only. If the byte is not equal to 06h, the
If more than 1 byte of data is sent, the PCA9674/74A does not acknowledge any
more.
STOP command to end the Software Reset sequence: the PCA9674/74A then resets
to the default value (power-up value) and is ready to be addressed again within the
specified bus free time. If the master sends a Repeated START instead, no reset is
performed.
2
C-bus master must interpret a non-acknowledge from the PCA9674/74A (at any
PCA9674/74A does not acknowledge it.
2
Device ID address
C-bus master.
2
S
START condition
C-bus is functional and that there is no device hanging the bus.
SWRST Call I
2
C-bus master.
0
0
Rev. 05 — 15 June 2009
0
2
0
Remote 8-bit I/O expander for Fm+ I
C-bus address
1
0
2
C-bus address ‘0000 000’ with the R/W bit set to 0 (write)
0
1
acknowledge
from slave(s)
0
1
2
R/W
C-bus master.
0
2
Registers are set to default power-up values.
C-bus command. To be performed correctly, it
1
A
0
1
0
SWRST data = 06h
0
0
PCA9674/74A is(are) reset.
002aac116
2
0
0
C-bus to be reset to the power-up
R/W
0
PCA9674/74A
1
acknowledge
from slave(s)
1
0
002aac262
2
C-bus with interrupt
Figure
A
© NXP B.V. 2009. All rights reserved.
P
10.
11 of 32

Related parts for PCA9674TS,112