MT8JSF25664HZ-1G4D1 Micron Technology Inc, MT8JSF25664HZ-1G4D1 Datasheet - Page 17

no-image

MT8JSF25664HZ-1G4D1

Manufacturer Part Number
MT8JSF25664HZ-1G4D1
Description
MICMT8JSF25664HZ-1G4D1 2GB DDR3 MODULE
Manufacturer
Micron Technology Inc
Series
-r
Datasheet

Specifications of MT8JSF25664HZ-1G4D1

Main Category
DRAM Module
Sub-category
DDR3 SDRAM
Module Type
204SODIMM
Device Core Size
64b
Organization
256Mx64
Total Density
2GByte
Maximum Clock Rate
1.333GHz
Operating Supply Voltage (typ)
1.5V
Operating Current
1.92A
Number Of Elements
8
Operating Supply Voltage (max)
1.575V
Operating Supply Voltage (min)
1.425V
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Pin Count
204
Mounting
Socket
Memory Type
DDR3 SDRAM
Memory Size
2GB
Speed
1333MT/s
Features
-
Package / Case
204-SODIMM
Lead Free Status / Rohs Status
Compliant
Table 19: Capability Register Bit Description (Continued)
Configuration Register
Table 20: Configuration Register (Address: 0x01)
Table 21: Configuration Register Bit Descriptions
PDF: 09005aef83364a85
jsf8c128_256x64hz.pdf - Rev. C 1/10 EN
Critical lock
Bit
RFU
0
1
2
3
4
5
15
bit
7
15:5
Bit
4:3
Description
Event mode
0: Comparator mode
1: Interrupt mode
EVENT# polarity
0: Active LOW
1: Active HIGH
Critical event only
0: EVENT# trips on alarm or critical temperature event
1: EVENT# trips only if critical temperature is reached
Event output control
0: Event output disabled
1: Event output enabled
Event status
0: EVENT# has not been asserted by this device
1: EVENT# is being asserted due to an alarm window
or critical temperature condition
Clear event
0: No effect
1: Clears the event when the temperature sensor is in
the interrupt mode
Alarm lock bit
Description
Temperature resolution
00: 0.5°C LSB
01: 0.25°C LSB
10: 0.125°C LSB
11: 0.0625°C LSB
0: Must be set to zero
RFU
14
6
1GB, 2GB (x64, SR) 204-Pin Halogen-Free DDR3 SDRAM SODIMM
Clear event
RFU
13
5
Temperature Sensor with Serial Presence-Detect EEPROM
Event output
status
RFU
12
4
Bit
Bit
17
Event output
control
RFU
11
3
Notes
Event mode cannot be changed if either of the lock
bits is set.
EVENT# polarity cannot be changed if either of the
lock bits is set.
This is a read-only field in the register. The event caus-
ing the event can be determined from the read tem-
perature register.
Micron Technology, Inc. reserves the right to change products or specifications without notice.
Critical event
only
10
2
Hysteresis
Event polarity
© 2010 Micron Technology, Inc. All rights reserved.
9
1
Event mode
Shutdown
mode
8
0

Related parts for MT8JSF25664HZ-1G4D1