CS5532-BS Cirrus Logic Inc, CS5532-BS Datasheet - Page 37

no-image

CS5532-BS

Manufacturer Part Number
CS5532-BS
Description
IC, ADC, 24BIT, 3.84KSPS, SSOP-20
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS5532-BS

Resolution (bits)
24bit
Sampling Rate
3.84kSPS
Input Channel Type
Differential
Data Interface
3-Wire, Serial
Supply Current
13mA
Digital Ic Case Style
SSOP
No. Of Pins
20
Rohs Compliant
No

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS5532-BS
Quantity:
8
Part Number:
CS5532-BSZ
Manufacturer:
CIRRUS
Quantity:
169
Part Number:
CS5532-BSZ
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
CS5532-BSZ
0
Company:
Part Number:
CS5532-BSZ
Quantity:
10
Company:
Part Number:
CS5532-BSZ
Quantity:
10
Part Number:
CS5532-BSZR
0
2.6.3. Examples of Using CSRs to Perform
Conversions and Calibrations
Any time a calibration or conversion command is
issued (C, MC, and CC2-CC0 bits must be properly
set), the CSRP2-CSRP0 bits in the command byte
are used as pointers to address one of the Setups in
the channel-setup registers (CSRs). Table 3 details
the address decoding of the pointer the bits.
The examples that follow detail situations that a
user might encounter when acquiring a conversion
or calibrating the converter. These examples as-
sume that the CSRs are programmed with the fol-
lowing physical channel order: 4, 1, 1, 2, 4, 3, 4, 4.
DS289PP5
FRS (WR3-WR0)
(CSRP2-CSRP0) CSR Location
0
0
0
1
1
1
1
1
1
1
1
1
1
Table 2. Conversion Timing for Continuous Mode
000
001
010
011
100
101
110
111
1010
0000
0001
0010
0100
1000
1001
1010
1011
1100
0011
1011
1100
Table 3. Command Byte Pointer
(First Conversion)
Clock Cycles
1581994 ± 10
107434 ± 10
205738 ± 10
402346 ± 10
795562 ± 10
15274 ± 10
21418 ± 10
33706 ± 10
58282 ± 10
CSR #1
CSR #1
CSR #2
CSR #2
CSR #3
CSR #3
CSR #4
CSR#4
17848 ± 8
28088 ± 8
48568 ± 8
2966 ± 10
Conversions)
Clock Cycles
Setup
(All Other
196608
393216
786432
10240
20480
49152
98304
12288
24576
1
2
3
4
5
6
7
8
5120
1536
3072
6144
A physical channel is defined as the actual input
channel (AIN1 to AIN4) to which an external sig-
nal is connected.
Example 1: Single conversion using Setup 1. The
command issued is ‘10000000’. This instructs the
converter to perform a single conversion referenc-
ing Setup 1 (CSRP2 - CSRP0 = ‘000’) In this ex-
ample, Setup 1 points to physical channel 4. After
the command is received and decoded, the ADC
performs a conversion on physical channel 4 and
SDO falls to indicate that the conversion is com-
plete. To read the conversion, 40 SCLKs are then
required. Once the conversion data has been read,
the serial port returns to the command mode.
Example 2: Continuous conversions using Setup 3.
The command issued is ‘11010000’. This instructs
the converter to perform continuous conversions
referencing Setup 3 (CSRP2 - CSRP0 = ‘010’). In
this example, Setup 3 points to physical channel 1.
After the command is received and decoded, the
ADC performs a conversion on physical channel 1
and SDO falls to indicate that the conversion is
complete. The user now has three options. The user
can acquire the conversion and remain in this
mode, acquire the conversion and exit this mode, or
ignore the conversion and wait for a new conver-
sion at the next update interval, as detailed in the
continuous conversion section.
Example 3: Calibration using Setup 4. This exam-
ple assumes that the OGS bit in the Configuration
Register is set to ‘0’. The command issued is
‘10011001’. This instructs the converter to perform
a self offset calibration referencing Setup 4
(CSRP2 - CSRP0 = ‘011’). In this example, Setup
4 points to physical channel 2. After the command
is received and decoded, the ADC performs a self
offset calibration on physical channel 2 and SDO
falls to indicate that the calibration is complete. To
perform additional calibrations, more commands
must be issued.
Note:
The CSRs need not be written. If they are not
CS5531/32/33/34
37

Related parts for CS5532-BS