VIPER28LDTR STMicroelectronics, VIPER28LDTR Datasheet - Page 24
![no-image](/images/manufacturer_photos/0/6/637/stmicroelectronics_sml.jpg)
VIPER28LDTR
Manufacturer Part Number
VIPER28LDTR
Description
OFFLINE POWER SUPPLY
Manufacturer
STMicroelectronics
Series
VIPer™ plusr
Datasheet
1.VIPER28HN.pdf
(32 pages)
Specifications of VIPER28LDTR
Output Isolation
Isolated
Frequency Range
54 ~ 66kHz
Voltage - Input
8.5 V ~ 23.5 V
Voltage - Output
800V
Power (watts)
20W
Operating Temperature
-25°C ~ 125°C
Package / Case
16-SOIC (0.154", 3.90mm Width)
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Operation descriptions
7.12
24/32
Extra power management function (EPT)
Some applications need an extra power for a limited time window during which the converter
regulation has to be guaranteed. The extra power management function allows to design a
converter that can satisfy this request and is provided by the EPT pin, see
page 8
This function requires the use of a capacitor on EPT pin (C
discharged by means of a 5 µA current cycle by cycle. When the drain current raises over
85% of Idlim value, see I
while when the drain current is below I
reaches the V
After the converter shut down, the V
threshold (typ. 14.5 V) and according to the auto restart operation
(see
threshold (typical, 4.5 V) in order to charge again the V
operation is enabled again only when the voltage on EPT pin, drop below the V
(typical, 0.6 V). The low C
ensures safe operations and avoids overheating in case of repeated overload events. The
value of C
can be connected to GND if the function is not used.
Section 7.5 on page 17
.
EPT
EPT
has to be selected in order to prevent the device overheating. The EPT pin
threshold (typical, 4 V), the converter is shut down.
DLIM_EPT
EPT
) the VDD pin voltage have to fall below the V
discharge current in combination with its low restart threshold,
Doc ID 15028 Rev 4
(
Table 8 on page 7
DD
DLIM_EPT
voltage will drop below the V
discharges the capacitor. If C
), the current generator charges C
DD
capacitor. Moreover the PWM
EPT
) that is charged or
DD(ON)
DD(RESTART)
Table 8 on
start up
EPT
EPT(RESTART)
‘s voltage
VIPER28
EPT