DSOX3024A-GSA AGILENT TECHNOLOGIES, DSOX3024A-GSA Datasheet - Page 21

OSCILLOSCOPE, 4 ANLG, 200MHZ, 4GSPS

DSOX3024A-GSA

Manufacturer Part Number
DSOX3024A-GSA
Description
OSCILLOSCOPE, 4 ANLG, 200MHZ, 4GSPS
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of DSOX3024A-GSA

Scope Type
Digital Bench
Scope Channels
4 Analog
Bandwidth
200MHz
Meter Display Type
WVGA Color
Sampling Rate
4GSPS
Input Impedance
1Mohm
Rise Time
1.75ns
Input Voltage
300V
Rohs Compliant
NA
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Performance characteristics
* Denotes warranted specifications, all others are typical.
** 2 mV/div is a magnification of 4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV for 2 mV/div sensitivity setting.
Acquisition modes
Characteristics
Normal
Peak detect
Averaging
High Resolution Mode
Segmented (optional)
Waveform measurements
Characteristics
Cursors**
Automatic measurements
Counter
Waveform math
Characteristics
Arithmetic
FFT
Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
All 3000 X-Series models
Capture glitches as narrow as 250-ps at all timebase settings
Selectable from 2, 4, 8, 16, 64, ... to 65,536
12 bits of resolution when ≥10 µs/div at 4 GSa/s or ≥20-µs/div at 2 GSa/s
Re-arm time = 1 µs (minimum time between trigger events)
All 3000 X-Series models
• Single cursor accuracy:
• Dual cursor accuracy:
Measurements continuously updated with statistics. Cursors track last selected
measurement. Select up to four measurements from the list below:
• Voltage: peak-to-peak, maximum, minimum, amplitude, top, base, overshoot, pre-shoot,
• Time: period, frequency, counter, + width, - width, burst width, duty cycle, rise time, fall time,
• Count: positive pulse count, negative pulse count, rising edge count, falling edge count
• Mixed: area- N cycles, area- full screen
Built-in frequency counter:
• Source: on any analog or digital channel
• Resolution: 5 digits
• Maximum frequency: bandwidth of scope
All 3000 X-Series models
f (g(t))
g(t): { 1, 2, 3, 4, 1-2, 1+2, 1x2, 3-4, 3+4, 3x4}
f(t): { 1-2, 1+2, 1x2, 3-4, 3+4, 3x4, FFT(g(t)), differentiate d/dt g(t), integrate ∫ g(t) dt, square
root √g(t) }
Where 1,2,3,4 represent analog input channels 1, 2, 3, and 4
Note: Channels 3 and 4 only available on MSO/DSOX3xx4A models
Up to 64 kpts resolution
Set FFT Window to: Hanning, Flat Top, Rectangular, Blackman-Harris
±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]
±[DC vertical gain accuracy + 0.5% full scale]*
average- N cycles, average- full screen, DC RMS- N cycles, DC RMS- full screen, AC RMS- N
cycles, AC RMS- full screen (standard deviation), ratio (RMS1/RMS2)
delay, phase, X at min Y, X at Max Y
21