DSOX3024A-GSA AGILENT TECHNOLOGIES, DSOX3024A-GSA Datasheet - Page 18

OSCILLOSCOPE, 4 ANLG, 200MHZ, 4GSPS

DSOX3024A-GSA

Manufacturer Part Number
DSOX3024A-GSA
Description
OSCILLOSCOPE, 4 ANLG, 200MHZ, 4GSPS
Manufacturer
AGILENT TECHNOLOGIES
Datasheet

Specifications of DSOX3024A-GSA

Scope Type
Digital Bench
Scope Channels
4 Analog
Bandwidth
200MHz
Meter Display Type
WVGA Color
Sampling Rate
4GSPS
Input Impedance
1Mohm
Rise Time
1.75ns
Input Voltage
300V
Rohs Compliant
NA
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Performance characteristics
* Denotes warranted specifications, all others are typical.
Vertical system digital channels
Characteristics
Digital input channels
Thresholds
Threshold selections
User-defined threshold range
Maximum input voltage
Threshold accuracy*
Maximum input dynamic range
Minimum voltage swing
Input impedance
Probe loading
Vertical resolution
Horizontal system analog channels
Characteristics
Maximum sample rate
Maximum record length
Maximum duration of time captured
at highest sample rate (all channels)
Time base range
(s/div)
Time base delay time range
Channel-to-channel deskew range
Time base accuracy*
∆ Time accuracy (using cursors)
Modes
XY
Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
DSOX3012A
MSOX3012A
5 ns/div to
50 s/div
DSOX3014A
MSOX3014A
5 ns/div to
50 s/div
All MSO 3000 X-Series models and on all DSO 3000 X-Series models with after
purchase upgrade
16 digital (D0 to D15)
Threshold per set of 8 channels
TTL (+1.4 V)
5 V CMOS (+2.5 V)
ECL (–1.3 V)
User-definable (selectable by pod)
±8.0 V in 10 mV steps
±40 V peak CAT I; transient overvoltage 800 Vpk
±(100 mV + 3% of threshold setting)
±10 V about threshold
500 mVpp
100 kΩ ±2% at probe tip
~8 pF
1 bit
All 3000 X-Series models
2 GSa/sec, 4 GSa/s half-channel interleaved
2 Mpts per channel, 4 Mpts half-channel interleaved
1 ms
All 3000 X-Series models
Pre-trigger – Greater of 1 screen width or 200 µs
Post-trigger – 1 s to 500 s
± 100 ns
25 ppm ± 5 ppm per year (aging)
±(time base acc. x reading) ± (0.0016 x screen width) ± 100 ps
Main, zoom, roll, XY
On channels 1 and 2 only Z Blanking on Ext Trigger Input, 1.4 V threshold Bandwidth:
Maximum bandwidth Phase error at 1 MHz: < 0.5 degree
DSOX3024A
MSOX3024A
2 ns/div to
50 s/div
18
DSOX3032A
MSOX3032A
2 ns/div to
50 s/div
DSOX3034A
MSOX3034A
2 ns/div to
50 s/div
DSOX3052A
MSOX3052A
1 ns/div to
50 s/div
DSOX3054A
MSOX3054A
1 ns/div to
50 s/div