FLUKE-190-202/AM/S Fluke, FLUKE-190-202/AM/S Datasheet

ScopeMeter, 200 MHz, 2 Channels Plus DMM/Ext.input, With SCC-290 Kit

FLUKE-190-202/AM/S

Manufacturer Part Number
FLUKE-190-202/AM/S
Description
ScopeMeter, 200 MHz, 2 Channels Plus DMM/Ext.input, With SCC-290 Kit
Manufacturer
Fluke
Datasheet

Specifications of FLUKE-190-202/AM/S

Scope Type
Hand Held
Scope Channels
2
Bandwidth
200MHz
Meter Display Type
LCD Color
Sampling Rate
2.5GSPS
Input Impedance
1Mohm
Supply Voltage Min
600V
Supply Voltage Max
1kV
Rohs Compliant
NA
Display
153 mm Full Color LCD
Equipment Type
Oscilloscopes
Lead Free Status / Rohs Status
 Details
ScopeMeter
ScopeMeter 190 Series II – the first
high-performance scopes built for
harsh industrial environments
Introducing the first high-performance portable oscil-
loscopes with 2 or 4 independently insulated input
channels, an IP51 dust- and dripwater proof rating and a
CAT III 1000 V/CAT IV 600 V safety rating. Choose from
200 MHz, 100 MHz or 60 MHz bandwidth models. Now
plant maintenance engineers can take a 2- or 4-channel
scope into the harsh world of industrial electronics.
190 Series II – a new generation of ScopeMeter
The 190 Series II include these capabilities:
Up to four independent floating isolated inputs, up to 1000 V
High-speed sampling: Up to 2.5 GS/sec on 2 channels simultaneously
Deep memory: 10,000 points per trace waveform capture (scope mode)
CAT III 1000 V/CAT IV 600 V safety rated for industrial environments
Up to seven hours of battery operation using BP291
Isolated USB host port for direct data storage to a USB memory device;
USB device port for easy PC communication
Easy access battery door for quick battery swaps in the field
Compact and only 2.2 kg (4.8 lb)
Security slot: lock down oscilloscope with Kensington
unattended
IP 51 rating, dust- and drip-proof
Connect-and-View
fast, slow and even complex signals
Frequency Spectrum using FFT-analysis
Automatic capture and REPLAY of 100 screens
ScopeRecord
frequency signal analysis
TrendPlot
automatic measurements
5,000 count DMM included in the 2-channel models
paperless recorder mode with deep memory for long-term
Roll mode gives 30,000 points per input channel for low
triggering for intelligent, automatic triggering on
®
190 Series II
®
lock while
Technical Data
®

FLUKE-190-202/AM/S Summary of contents

Page 1

ScopeMeter ScopeMeter 190 Series II – the first high-performance scopes built for harsh industrial environments Introducing the first high-performance portable oscil- loscopes with independently insulated input channels, an IP51 dust- and dripwater proof rating and a CAT ...

Page 2

... Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously ™ Video triggering (on ch. A) High-res, non-interlaced video Pulse width triggering (on channel A) Time delay Dual slope triggering N-cycle triggering 2 Fluke Corporation 2 Fluke Corporation ScopeMeter 190 Series II ScopeMeter 190 Series II 190-102 190-202 MHz 100 MHz 200 MHz 5 ...

Page 3

... Vrms between cursors, Watts between cursors Single vertical line Min-Max and Average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT Resultant ZOOM Ranges from full record overview to zoom sample level, at any record length ac and V (ac+dc) for PWM PWM ScopeMeter 190 Series II Fluke Corporation 3 ...

Page 4

... Voltmeter ranges Resistance Ranges Accuracy Other meter functions Continuity Diode test Current (A) Temperature 4 Fluke Corporation ScopeMeter 190 Series II 190-102 190-202 Via 4 mm banana inputs, fully isolated from scope inputs and scope ground One at a time 5,000 counts 1 MΩ ± ± Auto/manual ranging, relative measurements (Zero reference), TrendPlot The specified accuracy is valid over the temperature range 18 ° ...

Page 5

... Direct storage on external flash memory drive through USB host port 5 ms/div ~ 2 min/div 6 sec ~ 48 hr 0.5 s/div ~ 4 h/div 125 MS/s 200 μsec ~ 4.8 sec 190-104 190-204 Any combination of inputs channels All channels sampled simultaneously Single sweep, continuous roll, Start-on-Trigger (through any channel), Stop-on-Trigger (through any channel ScopeMeter 190 Series II Fluke Corporation 5 ...

Page 6

... Screen Replay sequence, or • a ScopeRecord Roll-mode recording ( traces), or • a TrendPlot recording measurements External data storage • On PC, using FlukeView • Direct storage on external flash memory drive (maximum 2 GB) through USB host port Screencopies • On PC, using FlukeView • Internally (in instrument) which can be copied on to external flash memory drive as .BMP-file, through ...

Page 7

... Li-Ion battery pack Voltage probe sets. Each set includes ground lead, hook clip, ground spring and probe tip insulation sleeve. Test leads Other multi-language users manuals on CD-ROM; FlukeView 190-062 190-102 190-202 0 °C ~ +40 °C; +40 °C ~ +50 °C excl. battery -20 °C ~ +60 °C +10 °C ~ +30 ° non-condensing; ...

Page 8

... Fluke 190-204/S Color ScopeMeter, 200 MHz, 4 channels, with SCC-290 kit included Fluke 190-104 Color ScopeMeter, 100 MHz, 4 channels Fluke 190-104/S Color ScopeMeter, 100 MHz, 4 channels, with SCC-290 kit included Fluke 190-202 Color ScopeMeter, 200 MHz, 2 channels plus DMM/Ext.input Fluke 190-202/S Color ScopeMeter, 200 MHz, 2 channels plus DMM/Ext.input, with ...