TLE6251G Infineon Technologies, TLE6251G Datasheet - Page 15

no-image

TLE6251G

Manufacturer Part Number
TLE6251G
Description
IC TXRX CAN STD HI SPEED 8SOIC
Manufacturer
Infineon Technologies
Type
Transceiverr
Datasheet

Specifications of TLE6251G

Package / Case
8-SOIC (3.9mm Width)
Number Of Drivers/receivers
1/1
Protocol
CAN
Voltage - Supply
4.75 V ~ 5.25 V
Mounting Type
Surface Mount
Product
Controller Area Network (CAN)
Number Of Transceivers
1
Data Rate
1 MBd
Supply Voltage (max)
5.25 V
Supply Voltage (min)
4.75 V
Supply Current (max)
10 mA
Maximum Operating Temperature
+ 150 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
SP000082094
TLE6251GNT
TLE6251GT
TLE6251GT

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE6251G
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Company:
Part Number:
TLE6251G
Quantity:
4 800
Local Failure-Flags and -Detection
TxD Dominant Failure Detection
RxD Permanent Recessive Clamping
TxD to RxD Short Circuit
Bus Dominant Clamping
Overtemperature Detection
Final Data Sheet
Effect: permanent dominant signal for
Indicator: NERR = LOW in RxOnly mode (local failure flag is set)
Action: disabling of the transmitter stage
Remarks: release of the transmitter stage only after transition into RxOnly mode (failure
diagnosis) and transition into normal mode.
Effect: internal RxD signal does not match signal at RxD pin because the RxD pin is pulled
to HIGH (permanent HIGH)
Indicator: NERR = LOW in RxOnly mode (local failure flag is set)
Action: disabling of the receiver stage
Remarks: the flag is cleared by changing from RxOnly (failure diagnosis) into normal mode
or RxD gets dominant.
Effect: short circuit between RxD and TxD
Indicator: NERR = LOW in RxOnly mode (local failure flag is set)
Action: disabling of the transmitter stage
Remarks: the flag is cleared by changing from RxOnly (failure diagnosis) into normal mode.
Effect: permanent dominant signal at the CAN bus for
Indicator: NERR = LOW in RxOnly mode (local failure flag is set)
Action: none
Remarks: none
Effect: junction temperature at the driving stages exceeded
Indicator: NERR = LOW in RxOnly mode (local failure flag is set)
Action: disabling of the transmitter stage
Remarks: the flag is cleared by changing from RxOnly (failure diagnosis) into normal mode
or RxD gets dominant. Bus only released after the next dominant bit in TxD.
t
>
t
TxD
15
at TxD
t
>
t
BUS
Rev. 3.2, 2006-04-05
TLE 6251 G