3601-95B-40 IEE (INDUSTRIAL ELECTRONIC ENGINEERS), 3601-95B-40 Datasheet - Page 32

Vacuum Fluorescent Display Panel

3601-95B-40

Manufacturer Part Number
3601-95B-40
Description
Vacuum Fluorescent Display Panel
Manufacturer
IEE (INDUSTRIAL ELECTRONIC ENGINEERS)
Datasheet

Specifications of 3601-95B-40

Resolution
2 X 20
Character Format
Dot Matrix
Viewing Area (h X W)
17.67mm X 93.8mm
Supply Current
370mA
Interface Type
Serial, Parallel
Operating Temperature Range
0°C To +55°C
Rohs Compliant
Yes
04/10/02
4.5
Industrial Electronic Engineers, Inc.
Van Nuys, California
Screen Control Codes
[A
30h
31h
Character Code
00h
01h
02h
04h
32h
33h
34h
35h
0
(RS) = High for the following Control Codes]
Set Display Screen or Column Brightness Level
Sets the display brightness level using a 3 byte command consisting of control code 30h, column
ID, and brightness level. Column ID code FFh sets all columns. Brightness levels range from 00h
(brightest) through 07h (dimmest). (Default is 00h)
Begin Blinking Character(s)
Sets the start of blinking character(s) or underbar(s) and the blink rate using a 2 byte command
consisting of control code 31h and blink code. Subsequent characters will blink until Control Code
32h is sent. (If a character is written at the current cursor location, that character will blink).
The “Underbar” and “Both” code sets apply only to 36X2–151–05240.
End Blinking Character(s)
Sets the end of blinking character(s) at the current cursor location. Subsequent characters will not
blink until Control Code 31h is sent. (A character written to the current cursor location will not
blink).
If a blinking character is overwritten by a non–blinking character, or if the Erase Line command is
executed, the blink attribute is turned off.
Blank Display Screen
Sets the display screen to OFF. Data and attribute settings are not affected.
Unblank Display Screen
Returns the display screen to ON after 33h.
Comma/Period/Triangle Function
35-01-n:
35-02-n:
35-03-n:
35-04-n:
Brightness levels must be set by columns rather than by
characters because of the construction of the vacuum
fluorescent tube.
display character with period
n = display character 20-FF
display character with comma
n = display character 20-FF
display character with comma & period
n = display character 20-FF
display character with triangle
n = display character 20-FF
Rate
OFF (Default) 60h
1 Hz
2 Hz
4 Hz
SCALE
SIZE
Underbar Code Rate
61h
62h
64h
A
Note
CODE IDENT NO.
N/A
05464
OFF
1 Hz
2 Hz
4 Hz
REV
Both Code
80h
81h
82
84h
N
SHEET
S036X2–XXX–XXXXX
Rate
OFF
1 Hz
2 Hz
4 Hz
31 of 49