TP3420AV309 National Semiconductor, TP3420AV309 Datasheet - Page 30

no-image

TP3420AV309

Manufacturer Part Number
TP3420AV309
Description
Manufacturer
National Semiconductor
Datasheet

Specifications of TP3420AV309

Number Of Line Interfaces
1
Control Interface
HDLC
Package Type
PLCC
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TP3420AV309
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
TP3420AV309/63
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
TP3420AV309/63SN
Manufacturer:
Texas Instruments
Quantity:
10 000
Part Number:
TP3420AV309/NOPB
Manufacturer:
Texas Instruments
Quantity:
10 000
www.national.com
0 (MFC INT)
5
10
15
20
25
0 (MFC INT)
5
10
15
20
25
0 (MFC INT)
5
10
15
20
25
0 (MFC INT)
5
10
15
20
25
0 (MFC INT)
SC1 Messaging Sequence
On the TE receive side, the LP, DTSE and FECV messages
are checked once, and for every occurrence an interrupt
is generated. The other messages are validated 3 times be-
fore an interrupt is generated. Subsequent repetitions of the
command do not cause an interrupt.
SC2 CHANNEL TRANSMITTER HANDLING
The software should keep a list of flags to indicate SC2 com-
mands as defined in the spec. At the 30 ms tick MFC INT, the
software should scan through the list of flags (top down) and,
Time
(ms)
I430 Frame Content
(IDLE)
(IDLE)
(IDLE)
(IDLE)
(IDLE)
(IDLE)
(IDLE)
(LB1I)
(LB1I)
(LB1I)
(LB1I)
(LB1I)
(LB1I)
(LB2I)
(LB2I)
(LB2I)
(LB2I)
(LB2I)
(LB2I)
(LRS)
(LRS)
(LRS)
(LRS)
(LRS)
(LRS)
SC1
(Continued)
if FL__EXT flag set, do not check for new flags on SC1L, but check for
SC2 channel. Reset FL__EXT. Send SC2 command as appropriate.
SC1L__NB (IDLE)
if FL__EXT flag not set, check for new flags on SC1L, assume LB1I.
Check for SC2 channel. Send SC2 command as appropriate.
SC1__NB(IDLE)
SC1__NB(LB1I)
if FL__EXT flag not set, Check for new flags on SC1L assume LB2I.
Check for SC2 channel. Send SC2 command as appropriate.
SC1__NB(LB1I)
SC1__NB(LB2I)
if FL__EXT flag not set, check for new flags on SC1L, assume IDLE.
Check for SC2 channel. Send SC2 command as appropriate.
SC1__NB(LB2I)
SC1__ NB(IDLE)
etc.
30
seeing the first flag, should write the appropriate command
in the MFT2 register and keep the value in SC2__NB (soft-
ware buffer).
On the TE receive side, the SC2 command is verified 3
times before an Interrupt is generated. Subsequent repeti-
tions of the command do not cause an interrupt.
>
>
>
>
>
>
>
MFT1L.
SC1__PB, SC1 command(LB2I)
MFT1L
SC1__PB, SC1 command (IDLE)
SC1__PB, SC1 command (LBL1I)
MFT1L.
MFT1L
Actions Required
>
>
>
SC1__NB,
SC1__NB
SC1__NB,