FPSI 1010 Lascar Electronics, FPSI 1010 Datasheet

no-image

FPSI 1010

Manufacturer Part Number
FPSI 1010
Description
Indicator; Red & Green; 0 to 5 VDC; 0.40%; 5 VDC (Typ.); 2.5 mA (Typ.); -30 de
Manufacturer
Lascar Electronics
Type
Electricalr
Datasheet

Specifications of FPSI 1010

Accuracy
0.4 %
Application
Go - no go indication, level monitoring, alarm indication, process control, automated test equipment
Connection Type
8-Way DIL
Cut Out, Panel
0.5×0.5 "
Dimensions
0.39"L×0.24"W×0.39"H
Display Color
Red & Green
Display Type
LED
Function
Level Indicator
Hysteresis
2 % (Typ.)
Input Impedance
1 Killohms (Typ.)
Input Voltage
2.5 VDC (Max.)
Internal Resolution
2.5 mV (Typ.)
Module Size
0.24 in. H x 0.39 in. L
Operating Temperature, Maximum
70 °C
Operating Temperature, Minimum
-30 °C
Range, Measurement
0 to 2.5 VDC, 0 to 5 VDC
Supply Current
2.5 mA (Typ.)
Supply Voltage
5 VDC (Typ.)
Temperature, Stability
100 ppm⁄°C (Typ.)
Voltage, Supply
5 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
FPSI 1010
Specifications liable to change without prior warning
PRODUCT DESCRIPTION
The FPSI 1010 uses the latest miniaturisation techniques to produce a very compact voltage level indicator.
compares an input voltage to a defined voltage window. The colour of the display shows whether the input voltage is below,
within or above this window.
voltage range. The user can easily set the colour switching thresholds (an optional programmer is available - FPSI 1010
PROG). Hysteresis is included to avoid chattering at the colour switching thresholds. The module incorporates three outputs,
one for each colour level, allowing the user to drive external alarms or to control the process being monitored. A low power
mode is also available, whereby the module indicates the voltage level by flashing the relevant colour, instead of indicating
solid colours. Connection to the 10x10mm module is via 8-way DIL pins. This unique product is designed to be a drop-in
component in most medium and high volume applications, ranging from personal instrumentation and integral sensor
indicators to control panel status displays. This module is supplied with a plastic mounting bezel,
(0.5 x 0.5") cut-out.
FEATURES
TYPICAL APPLICATIONS
• Go - No Go Indication
• Level Monitoring
• Alarm Indication
• Process Control
• Automated Test Equipment
ELECTRICAL SPECIFICATIONS
SAFETY
To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed 60Vdc. The
user must ensure that the incorporation of the panel meter into the user’s equipment conforms to the relevant sections of BS
EN 61010 (Safety Requirements for Electrical Equipment for Measuring, Control and Laboratory Use).
• Bright Red and Green Indication
• 0 to 2.5Vd.c. and 0 to 5.0Vd.c. Measurement Ranges
• 2 User Programmable Thresholds
• 5V d.c. Supply Voltage
• Low Power Mode
• Easy to Set up and Use
• 8-Pin DIL Package
• Module can be customised on request
Specification
Supply voltage (V+ to 0V)
Supply current
Input Voltage (Vin to 0V) Vref not connected
Internal resolution
Accuracy (overall error)
Temperature stability
Hysteresis
Sample rate
Operating temperature range
Input impedance
Output High Voltage (pins 5, 6, 7)
Output High Current (pins 5, 6, 7)
Output Low Voltage (pins 5, 6, 7)
Output Low Current (pins 5, 6, 7)
* Operation of the indicator beyond the maximum supply voltage rating may cause permanent damage to the indicator.
Display not flashing
Display flashing (average current)
Vref connected to +5.0V
Vref not connected
Vref connected to +5.0V
The indicator provides a red-green-red bright LED indication over a 0 to 2.5V or 0 to 5V input
FPSI 1010
V+ - 0.7
Min.
4.75
-30
0
0
0
Issue 6
ORDERING INFORMATION
Standard Indicator
Programmer
Typ.
100
2.5
2.5
5.0
0.4
15
5
2
4
1
2 Colour Voltage Level Indicator
Max.
5.5*
+70
V+
2.5
5.0
0.6
1
1
IRCN
M.C.
, requiring a 12.6 x 12.6mm
: 716 - Page 1 of 4
Applies to FPSI 1010/1
Stock Number
FPSI 1010
FPSI 1010 PROG
Samples/sec
ppm/°C
kOhm
V d.c.
V d.c.
V d.c.
Unit
Vd.c.
Vd.c.
mA
mA
mV
mV
mA
mA
°C
%
%
The module

Related parts for FPSI 1010

FPSI 1010 Summary of contents

Page 1

... The indicator provides a red-green-red bright LED indication over 2. input voltage range. The user can easily set the colour switching thresholds (an optional programmer is available - FPSI 1010 PROG). Hysteresis is included to avoid chattering at the colour switching thresholds. The module incorporates three outputs, one for each colour level, allowing the user to drive external alarms or to control the process being monitored ...

Page 2

... Switching from Red2 to Green GREEN V1 Switching from Green to Red1 RED1 0V Colour switching levels with Vin falling. Hysteresis is built into the FPSI 1010. It cannot be switched off. Specifications liable to change without prior warning 10.0 (0.39) 1.27 (0.05) 0.46 2.54 (0.10) (0.02) PIN CONFIGURATION ...