Description
Panel Meter, Digital, 3 1/2 digits, 120 VAC Supply, Range 200 DCV
Manufacturer
Simpson
Type
Voltager
Datasheet

Specifications of F35-3-14-0

Accuracy
±0.1% %
Connection Type
Screw
Cut Out, Panel
1/8 DIN
Dimensions
3.78"L×2.94"D×1.89"H
Display Digit Height
0.56 "
Display Resolution
100 mV
Display Type
LED
Function
Voltage
Material, Casing
Noryl
Number Of Digits
3-1/2
Primary Type
Electronic
Range, Measurement
200 VDC
Voltage, Supply
9 to 32 VDC
A manufacturing plant requires a low cost
digital meter to replace an analog panel meter
on a 150VDC motor. The upgrade is required
because the operator requires a display hold
feature that is not available on the analog
model.
A Falcon 3-1/2 digit indicator (200DCV) can fit
this application. The meter needs no addition-
al scaling before being installed into the panel.
A switch is required for the display hold option,
as one is not supplied by Simpson.
The meter is installed in parallel with the motor
like the analog meter, and is ready to be
placed in the panel.
The Falcon is less than 3" deep, fitting well
into the restricted panel space. It will take up
about as much space as the analog meter it
replaced. In addition, display hold is a stan-
Switchboard
Portable
Accessories
3-1/2 Digit Indicator
Ordering Information
Application Example
F35 Basic Unit Power Supply
F35
1
2
3
4
*Meets CE EMI EN-50082-1, EN-55022, EN-61000-3-2, EN-61000-3-3
120VAC
220VAC*
9-32VDC
120VAC*
External shunts enable DC volt
digital panel meters to indicate
higher DC currents than can be
provided with self contained inter-
nal shunt meters.
installed in series with the load
and the source. The shunts pro-
vide a DCmV drop which is sent
to the display unit.
can be scaled to display the cur-
rent between the load and the
source. Simpson offers portable
and switchboard shunts.
Each shunt includes 5’ leads
(0.065
within
1% of rating.
resistance). Accuracy is
dard feature on the Falcon. By shorting con-
nections #3 and #4, the operator can hold the
display to take a reading, and then remove
the short to reactivate the indication mode.
11
12
13
14
The shunt is
Range
The Falcon
200mV
200V
20V
2V
Amp
100
150
200
100
200
100
200
10
15
20
25
30
50
75
10
30
10
20
1
5
Excitation
0
1
2
Voltage
100mV
100mV
100mV
100mV
200mV
200mV
200mV
200mV
50 mV
None
12VDC
24VDC
50mV
50mV
50mV
50mV
50mV
50mV
50mV
50mV
50mV
50mV
50mV
Drop
Portable Shunts ( 50 mV )*
Motor
Falcon 200VDC
Across R114 Readout
Jumper
None
None
None
None
None
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Ordering Information
A switch can be used to short the connec-
tions. The meter is shipped ready to install,
keeping down-time to a minimum.
Range of
100.0
10.00
100.0
199.9
1.00
5.00
10.0
15.0
20.0
25.0
30.0
50.0
75.0
10.0
30.0
20.0
Supply
100
150
200
200
Safety Symbols
Number
Catalog
06700
06706
06704
06705
06707
06708
06709
06711
06713
06714
06715
06716
06717
N/A
N/A
N/A
N/A
N/A
N/A
N/A
The WARNING sign denotes
a hazard. It calls attention
to a procedure, practice, or
the like, which, if not cor-
rectly performed or adhered
to, could result in personal
injury.
The CAUTION sign denotes
a hazard. It calls attention
to an operating procedure,
practice, or the like, which,
if not correctly adhered to,
could result in damage to or
destruction of part or all the
instrument.
**All
require a jumper across R114.
A portable or switchboard
shunt should be used with
Falcon series 200 mVDC
meters. Specifications can
be found on data sheet for
DC Voltage.
Switchboard (50 mV)**
Amp Voltage
100
150
200
250
300
400
500
switchboard
50mV
50mV
50mV
50mV
50mV
50mV
50mV
Drop
Number
Catalog
06500
06503
06504
06505
06506
06507
06508
shunts

Related parts for F35-3-14-0