F35-3-14-0 Simpson, F35-3-14-0 Datasheet - Page 2

no-image

F35-3-14-0

Manufacturer Part Number
F35-3-14-0
Description
Panel Meter, Digital, 3 1/2 digits, 120 VAC Supply, Range 200 DCV
Manufacturer
Simpson
Type
Voltager
Datasheet

Specifications of F35-3-14-0

Accuracy
±0.1% %
Connection Type
Screw
Cut Out, Panel
1/8 DIN
Dimensions
3.78"L×2.94"D×1.89"H
Display Digit Height
0.56 "
Display Resolution
100 mV
Display Type
LED
Function
Voltage
Material, Casing
Noryl
Number Of Digits
3-1/2
Primary Type
Electronic
Range, Measurement
200 VDC
Voltage, Supply
9 to 32 VDC
DISPLAY
Type: 7-segment, red LED
Height: 0.56" (14.2mm)
Decimal Point: 3-position programmable,
internally or on the terminal block
Overrange indication: most significant
digit = “1”; other digits blank
Polarity: Automatic, with "-" indication,
"+" indication implied
POWER REQUIREMENTS
AC Voltages: 120 or 220VAC, ±10%,
50/60Hz
DC Voltages: 9-32VDC, ±1%
Power Consumption: 3VA
ACCURACY @25º C
±0.1% of reading ±1 count
750 ±2 counts
All Falcon Indicators are configured initially per the customer specifica-
tions. Range changes can be accomplished as follows:
Disconnect power from the unit. Remove the unit from the panel.
Remove the front bezel by inserting slotted screwdriver in the vertical
slots on either side of the bezel and then turning to pry the bezel off.
Unscrew the two Phillips head screws at either side of the circuit board.
Finally, push on the green connector assembly in the back of the unit
to slide the main circuit board out from the meter. Change jumpers
according to the chart below.
Note: If a new range is selected, the calibration procedure must also
be performed.
Input Signal: Connect the signal to be monitored to the IN HI and
IN LO terminals. IN HI is terminal #1, IN LO is terminal #2.
Supply Power: Connect the supply power to terminals #11 and
#12. Note that if AC power is supplied, terminal #11 is for Neutral,
and terminal #12 is for Hot. If DC power is used, terminal #11 is for
-DC, and #12 is for +DC.
Display Hold: This feature allows you to hold the displayed value
indefinitely. A remote switch can be used to make the connection.
To activate the display hold, short terminal blocks #3 and #4 (Hold
Ref and +Ref). This connection must be kept isolated from other
circuitry. To hold multiple units, separate poles of the switch must
be used to maintain the isolation.
* 750 volt range may be configured by factory or Simpson Authorized Service Center only.
Wiring Diagram
Specifications
1
Voltage Range Selection
2
200mV
Range
200V
Input
20V
2V
3
Before switching the instrument on, make sure the supply volt-
age matches the power source required of the instrument as
indicated on the hook-up label affixed to the instrument.
These instruments are designed for maximum safety to the
operator when mounted in a panel according to instructions.
They are not to be used unmounted or for exploratory mea-
surements in unknown circuits.
4
J103
C
A
B
D
5
J106
6
R
R
R
R
7
JU101
V
V
V
V
8
9
JU102
Yes
No
No
No
ENVIRONMENTAL
Operating Temperature: 0 to 55ºC
Storage Temperature: -10 to 60ºC
Relative Humidity: 0 to 85% non-condensing
Temperature Coefficient:
(±0.01% of input ± 0.05 count)/ºC
Warm-up Time: Less than 15 minutes
Response Time: Less than 1 second
NOISE REJECTION
NMRR: 50dB, 50/60Hz
CMRR: (with 1K
90dB min.
ANALOG TO DIGITAL CONVERSION
Technique: Dual slope integration
Rate: 3 samples per second, nominal
10
11 12
unbalanced @ 60Hz):
Note: JU101 and JU102 are hard wire jumpers, and are removed by
cutting them. Resoldering the JU jumpers is not recommended. If this is
required, or if a function is to be changed (from volts to current), Simpson
recommends returning the Falcon to the factory or an Authorized Service
Center. After moving the jumpers to the desired location, put the Falcon
back together and install in your panel, or proceed to calibration.
From terminal block: The decimal point can be set from the rear
screw terminal block by connecting the appropriate decimal point
(DP 1, 2, 3, ) to the DP C terminal. The J105 jumper must be in the
D position (see diagram under "From front panel").
From front panel: The decimal point can also be selected by
removing the front bezel from the meter. Move the push-on jumper
J105 across the correct letter.
Decimal
1.999
19.99
199.9
1999
Decimal
1.999
19.99
199.9
1999
* No Decimal Point
Point
Point
Decimal Point Selection
See Chart
Position at J105
DP C to DP1
DP C to DP2
DP C to DP3
No Decimal
Jumper
Connect
A
B
C
D*
MECHANICAL
Bezel: 3.79"x 1.89" x .44"
Depth: 2.94" (74.7mm)
Panel Cutout: 3.6" X 1.77"
Case Material: 94V-1, UL rated Noryl®
Weight: 9.0oz (255.1g)
INPUTS: DC Voltage
JUMPER POSITION
AT "R" ON J106
T101
200mV
Range
Input
200V
20V
2V
1
(96 x 48 x11.2mm)
J104
J101
2
A B C D E
J106
Resolution
3
JU106 JU112
J102
R
Display
100mV
100 V
10mV
(91.9 x 45mm 1/8 DIN)
1mV
JU101
A
A
4
J103
JU102
V
5
JUMPER
POSITION
AT "A" ON J101
FOR AMPS
"V" FOR VOLTS
JUMPER
POSITION
AT "A" ON J103
FOR 2V.
6
Impedance
7
10M
10M
10M
100M
Input
8
9
10 11 12
Maximum
Overload
100V
100V
250V
50V