DTX-1800 120 FLUKE NETWORKS, DTX-1800 120 Datasheet - Page 3

no-image

DTX-1800 120

Manufacturer Part Number
DTX-1800 120
Description
Cable Analyzer
Manufacturer
FLUKE NETWORKS
Type
Networkr
Datasheet
** Note: all specifications for tests on twisted-pair cabling apply to 100 Ω cable. Contact Fluke Networks for information on measurement
Above specifications are subject to change without notice.
Environmental Specifications
Operating temperature
Storage temperature
Operating relative humidity
(% RH without condensation)
Vibration
Shock
Safety
Pollution degree
Altitude
EMC
Performance Specifications**
Baseline accuracy
Category 6A/Class EA link test modes
(and lower link categories)
Class F link test modes
Length for Twisted Pair Cabling
Parameter
Range
Resolution
Accuracy
Propagation Delay
Parameter
Range
Resolution
Accuracy
Delay Skew
Parameter
Range
Resolution
Accuracy
DC Loop Resistance Test
Parameter
Range
Resolution
Accuracy
Overload recovery time
Length specs do not include the uncertainty of the cable’s NVP Value
performance for cable with a different impedance.
1
32° F to 104° F (0° C to 45° C)
-4° F to +140° F (-20° C to +60° C)
32° F to 95° F (0° C to 35° C): 0 % to 90 %
95° F to 113° F (35° C to 45° C): 0 % to 70 %
Random, 2 g, 5 Hz -500 Hz
1 m drop test with and without module and adapter attached
CSA C22.2 No. 1010.1: 1992
EN 61010-1 1st Edition + Amendments 1, 2
Pollution Degree 2 as defined in IEC 60664 and applied to IEC 60950 ‘Safety of Information
Technology Equipment, 1999’
Operating: 4000 m; Storage: 12000 m
EN 61326-1
The baseline accuracy of all DTX Series testers meets or exceeds the requirements of Level IV
as in draft 2nd Edition of IEC 61935-1 over the frequency range supported by the tester.
DTX CableAnalyzer far exceeds Level IIIe requirements of TIA/EIA-568-B.2-10 and IEC 61935-1.
DTX-1800 is compliant with Level IV requirements as in the draft 2nd edition of IEC 61935-1.
Single-ended test
4000 ns
1 ns
± (2 ns + 2%); 0 to 750 ns
± (2 ns + 4%); 751 to 4000 ns
Single-ended test
4000 ns
1 ns
± (2 ns + 2%); 0 to 750 ns
± (2 ns + 4%); 751 to 4000 ns
Twisted Pair Cabling
0 ns to 100 ns
1 ns
± 10 ns
Twisted Pair Cabling
O Ω to 53 Ω
0.1 Ω
± (1 Ω + 1%)
Less than 10 minutes to rated accuracy following over-voltage. Referencing is required after
repeated or prolonged over-voltage.
Dual-ended test (Main and Remote)
150 m (490 ft)
0.1 m or 1 ft
± (2 ns + 2%)
Dual-ended test (Main and Remote)
750 ns
1 ns
± (2 ns + 2%)
N E T W O R K
Fluke Corporation
P.O. Box 777, Everett, WA USA 98206-0777
Fluke Networks operates in more than 50 countries
worldwide. To find your local office contact details,
go to www.flukenetworks.com/contact.
©2009 Fluke Corporation. All rights reserved.
Printed in U.S.A. 7/2009 2131195C B-ENG-N