AVL4000-N04-5DZM SMC Corporation, AVL4000-N04-5DZM Datasheet - Page 2

no-image

AVL4000-N04-5DZM

Manufacturer Part Number
AVL4000-N04-5DZM
Description
Valve, Soft Start Up w/ Lock Out and Solenoid Valve 24VDC, Port Size 1/2
Manufacturer
SMC Corporation
Type
Soft Start Upr
Datasheet

Specifications of AVL4000-N04-5DZM

Body Size
1⁄2
Brand/series
AV Series
Coil Voltage
24 VDC
Configuration
with Lock Out
Connection Type
D Type DIN with M12 Connector, Indicator Light and Voltage Suppressor
Pressure Range
30 to 150 psi
Primary Type
Solenoid Valve
Size, Port
1⁄2" NPT
Temperature, Ambient
32° to 140°F
Terminal Type
D Type DIN Connector
Thread Type
1⁄2" NPT
Valve Type
Soft Start Up
Voltage, Coil
24 VDC
1. Actuator drive
2. Holding pressure
3. Maintenance space
1. Confirm the specifications.
2. Extended periods of continuous energization
3. Operation of closed center solenoid valves
4. Using a regulator in the outlet side
5. Operation of solenoid valves in the outlet side
6. Operation
7. Using a lubricator
8. Operation for air blowing
14-3-2
Be sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and Common Precautions.
When using solenoid valve or actuator in the outlet side of this
product, implement appropriate measures to prevent potential
danger caused by actuator operation.
Since the valve might have slight interal leakage, it is not
suitable for holding pressure in a tank or another vessel for a
long period of time.
Allow the sufficient space for maintenance and inspection.
The products presented in this catalog are designed only for
use in compressed air systems. Do not operate at pressures
or temperatures, etc., beyond the range of specifications, as
this
specifications.) Please contact SMC if using for other fluids
than compressed air.
Please contact SMC if valves will be continuously energized
for extended periods of time.
Even if this product is used for closed center solenoid valves
or actuator with a load factor of more then 50%, jumping
(stick-slip phenomenon) cannot be prevented.
When mounting a regulator in the outlet side (A port side), use
a residual pressure relief regulator (AR25K to 40K) or a check
type regulator. With a standard regulator (AR10 to 60), the
outlet side pressure may not be released when this valve is
exhausted.
To operate solenoid valves mounted on this product’s outlet
side (A port side), first confirm that the outlet side’s pressure
(P) has increased to become equal to the inlet side’s pressure
(P).
The residual pressure release function of this product is for
emergency use only; therefore, avoid the operation in the
same manner as ordinary 3 port valves.
If mounting a lubricator, mount it on the inlet side (P port side),
of this product. If mounted on the outlet side (A port side),
back flow of oil will occur and may spurt out of the valve’s R
port.
This product cannot be operated for air blowing due to the
mechanism that switches the main valve to be fully open after
the outlet side’s pressure increases to approximately 1/2 of the
inlet side.
Warning
Warning
can
cause damage
Caution on Design
Selection
or
malfunction.
(Refer
Precautions
to
1. Voltage leakage
2. Low temperature operation
1. If air leakage increases or equipment does not
2. Instruction manual
3. Painting and coating
1. To perform the initial speed adjustment of a outlet
AC coil is 20% or less of rated voltage.
DC coil is 3% or less of rated voltage.
Particularly when using a C-R element (surge voltage
suppressor) for protection of the switching element, use cation
that leakage voltage will increase due to leakage current
flowing through the C-R element, etc.
Although the valve can be operated at temperature as low as
0°C, measures should be taken to avoid solidifying or freezing
drainage and moisture, etc.
operate properly, stop operation.
After mounting or maintenance, etc., connect the compressed
air and power supplies, and perform appropriate function and
leakage tests to confirm that the unit is mounted properly.
Mount and operate the product after reading the manual
carefully and understanding its contents. Also keep the
manual in a place where it can be referred to as necessary.
Warnings or specifications printed or labeled on a product
should not be erased, removed or covered up.
Furthermore, please contact SMC before painting the resin
parts, as this may cause adverse effects depending on the
solvent.
side actuator, supply air from this valve’s inlet side
and turn ON the pilot valve. Then, rotate the needle
clockwise from the fully closed position.
Caution
Caution
Warning
Power
supply
Switching element
Adjustment
Leakage current
Mounting
Selection
Resistor
OFF
Valve