3130-F110-P7T1-W01Q-3A E-T-A Circuit Protection and Control, 3130-F110-P7T1-W01Q-3A Datasheet - Page 2

no-image

3130-F110-P7T1-W01Q-3A

Manufacturer Part Number
3130-F110-P7T1-W01Q-3A
Description
Circuit Breaker; Therm; Rocker; Cur-Rtg 3A; Snap-In Frame; 1 Pole; Blade Snap; Thermal
Manufacturer
E-T-A Circuit Protection and Control
Type
Thermalr
Datasheet

Specifications of 3130-F110-P7T1-W01Q-3A

Actuator Type
Rocker
Application
For motors, transformers, solenoids, household and office machines, electrical tools, mobile homes, boating, construction vehicles, medical
Brand/series
3130 Series
Characteristic
Thermal
Color, Button
Black
Current, Rating
3 A
Dielectric Strength
3000 VAC
Dimensions
1.34"Lx0.571"Wx1.3"H
Mounting Hole Size
1.34x0.575 "
Mounting Type
Snap-In Frame
Number Of Poles
1
Resistance, Insulation
100 Megohms (Min.) @ 500 VDC
Standards
CBE Standard EN 60934 (IEC 60934), UL Listed, CSA Certified
Temperature, Operating, Maximum
60 °C
Temperature, Operating, Minimum
-30 °C
Termination
Blade
Voltage, Rating
240/50 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
Single, two and three pole rocker switch/thermal trip free circuit breakers
(S-type TO CBE to EN 60934) of compact design for snap-in panel
mounting. Available either with protection on one/both/all poles or, in the
case of the double pole version, protection on one pole only. Illumination
is optional and there is a choice of rocker colours.
Approved to CBE standard EN 60934 (IEC 60934).
Motors, transformers, solenoids, household and office machines, electrical
tools, mobile homes, boating, construction vehicles, medical equipment
to EN 60601.
Current
rating (A)
0.1
0.2
0.3
0.4
0.5
0.8
1
1.2
1.5
2
2.5
3
3.5
operating voltage
6 V
12 V
24 V
48 V
115 V
230 V
415 V
* single pole version only
Authority
VDE (EN 60934)
UL, CSA
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
Description
Typical applications
Standard current ratings and typical internal resistance values
Illumination voltage/power consumption
Approvals
Internal resistance
per pole (Ω)
94
24
12
5.30
4.20
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Voltage rating
AC 240/415 V
DC 50 V
DC 28 V
AC 250 V; DC 50 V
3 AC 250 V
Thermal Overcurrent Circuit Breaker 3130
filament/neon (B)
60 mA
20 mA
20 mA
20 mA
< 1.5 mA
< 1.5 mA
< 1 mA
power consumption
Current
rating (A) per pole (Ω)
4
5
6
7
8
10
12
14
15
16
18
20
Current rating
0.1...20 A
0.1...16 A
0.1...8 A
0.1...16 A
0.1...20 A
0.1...16 A
0.1...12 A
Internal resistance
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
LED (G, R, Y)
9 mA
9 mA
9 mA
1.5 mA
< 1 mA*
< 1 mA*
not available
single pole
multipole
multipole
single pole
1- and 2- pole
3-pole
single pole
For further details please see chapter: Technical Information
Voltage rating
Current ratings
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A)
Dielectric strength
(IEC 60664 and 60664A)
Insulation resistance
Interrupting capacity I
Interrupting capacity
(UL 1077)
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Shock
Corrosion
Humidity
Mass
Technical data
AC 240 V:
DC 50 V:
DC 28 V:
AC 240 V:
DC 50 V:
3 AC 415 V: 0.1...16 A 30,000 operations at 1 x I
operating area
current path/current path AC 1,500 V
1-pole
0.1...20 A 30,000 operations at 1 x I
0.1...4 A
4.5...16 A 30,000 operations at 1 x I
4.5...20 A 30,000 operations at 1 x I
0.1...16 A 50,000 operations at 1 x I
0.1...16 A 50,000 operations at 1 x I
cn
AC 240 V; 3 AC 415 V; DC 50 V
(UL: AC 250 V; 3 AC 250 V; DC 50 V)
0.1...20 A
0.1...16 A
1-pole
30,000 operations at 1 x I
2-pole
3-pole
-30...+60 °C (-22...+140 °F)
rated impulse
2.5 kV
reinforced insulation in operating area
test voltage
AC 3,000 V
> 100 MΩ (DC 500 V)
0.1...2 A
2.5...20 A
2.5...16 A
2.5...12 A
14 + 16 A
I N
1- + 2-pole AC 250V/3500A AC 250V/3500A
3-pole
1- + 2-pole DC 50V/2000A
operating area IP40
terminal area IP00
5 g (57-500 Hz) ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
1-pole: 25 g (11 ms) 2 + 3-pole: 20 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-3, test Ca
approx. 45 g (three pole)
approx. 31 g (double pole)
approx. 17 g (single pole)
withstand voltage
3130
0.1...12 A
3AC 250V/5000A
1-pole
2- and 3-pole
10 x I
150 A
250 A
150 A
130 A
3-pole
N
pollution
degree
2
N
N
N
N
N
N
N
, inductive
, inductive
, resistive
, inductive
, inductive
, inductive
, inductive
14...16 A
DC 50V/2000A
1-pole
2-pole
3-pole
3-pole
1 - 75
1

Related parts for 3130-F110-P7T1-W01Q-3A