3130-F110-H7T1-W02Q-15A E-T-A, 3130-F110-H7T1-W02Q-15A Datasheet

no-image

3130-F110-H7T1-W02Q-15A

Manufacturer Part Number
3130-F110-H7T1-W02Q-15A
Description
CIRC BRKR/SWITCH SP 15A SCREW TM
Manufacturer
E-T-A
Series
3130r
Datasheet

Specifications of 3130-F110-H7T1-W02Q-15A

Breaker Type
Thermal
Voltage
50VDC, 250VAC
Current - Trip (it)
15A
Number Of Poles
1
Actuator Type
Rocker
Mounting Type
Panel Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
3130-F110-H7T1-W02Q-15AMP
3130F110H7T1W02Q
Q2066900A
Single, two and three pole rocker switch/thermal trip free circuit breakers
(S-type TO CBE to EN 60934) of compact design for snap-in panel
mounting. Available either with protection on one/both/all poles or, in the
case of the double pole version, protection on one pole only. Illumination
is optional and there is a choice of rocker colours.
Approved to CBE standard EN 60934 (IEC 60934).
Motors, transformers, solenoids, household and office machines, electrical
tools, mobile homes, boating, construction vehicles, medical equipment
to EN 60601.
Current
rating (A)
0.1
0.2
0.3
0.4
0.5
0.8
1
1.2
1.5
2
2.5
3
3.5
operating voltage
6 V
12 V
24 V
48 V
115 V
230 V
415 V
* single pole version only
Authority
VDE (EN 60934)
UL, CSA
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.
Issue B
Description
Typical applications
Standard current ratings and typical internal resistance values
Illumination voltage/power consumption
Approvals
Internal resistance
per pole (Ω)
94
24
12
5.30
4.20
1.50
0.9
0.80
0.45
0.27
0.0785
0.0595
0.0565
Voltage rating
AC 240/415 V
DC 50 V
DC 28 V
AC 250 V; DC 50 V
3 AC 250 V
Thermal Overcurrent Circuit Breaker 3130
filament/neon (B)
60 mA
20 mA
20 mA
20 mA
< 1.5 mA
< 1.5 mA
< 1 mA
power consumption
Current
rating (A) per pole (Ω)
4
5
6
7
8
10
12
14
15
16
18
20
Current rating
0.1...20 A
0.1...16 A
0.1...8 A
0.1...16 A
0.1...20 A
0.1...16 A
0.1...12 A
Internal resistance
0.0435
0.0325
0.0215
0.0165
0.0165
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
LED (G, R, Y)
9 mA
9 mA
9 mA
1.5 mA
< 1 mA*
< 1 mA*
not available
single pole
multipole
multipole
single pole
1- and 2- pole
3-pole
single pole
www.e-t-a.com
Current ratings
Typical life
Dielectric strength
(IEC 60664 and 60664A)
Interrupting capacity
Shock
Corrosion
Humidity
Mass
For further details please see chapter: Technical Information
Voltage rating
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664 A)
Insulation resistance
Interrupting capacity I
(UL 1077)
Degree of protection
(IEC 60529/DIN 40050)
Vibration
Technical data
AC 240 V:
DC 50 V:
DC 28 V:
AC 240 V:
DC 50 V:
3 AC 415 V: 0.1...16 A 30,000 operations at 1 x I
operating area
current path/current path AC 1,500 V
1-pole
0.1...20 A 30,000 operations at 1 x I
0.1...4 A
4.5...16 A 30,000 operations at 1 x I
4.5...20 A 30,000 operations at 1 x I
0.1...16 A 50,000 operations at 1 x I
0.1...16 A 50,000 operations at 1 x I
cn
AC 240 V; 3 AC 415 V; DC 50 V
(UL: AC 250 V; 3 AC 250 V; DC 50 V)
0.1...20 A
0.1...16 A
1-pole
30,000 operations at 1 x I
2-pole
3-pole
-30...+60 °C (-22...+140 °F)
rated impulse
withstand voltage
2.5 kV
reinforced insulation in operating area
test voltage
AC 3,000 V
> 100 MΩ (DC 500 V)
0.1...2 A
2.5...20 A
2.5...16 A
2.5...12 A
14 + 16 A
I N
1- + 2-pole AC 250V/3500A AC 250V/3500A
3-pole
1- + 2-pole DC 50V/2000A
operating area IP40
terminal area IP00
5 g (57-500 Hz) ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
1-pole: 25 g (11 ms) 2 + 3-pole: 20 g (11 ms)
to IEC 60068-2-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
approx. 45 g (three pole)
approx. 31 g (double pole)
approx. 17 g (single pole)
3130
0.1...12 A
3AC 250V/5000A
1-pole
2- and 3-pole
10 x I
150 A
250 A
150 A
130 A
3-pole
N
pollution
degree
2
N
N
N
N
N
N
N
, inductive
, inductive
, resistive
, inductive
, inductive
, inductive
, inductive
14...16 A
DC 50V/2000A
1-pole
2-pole
3-pole
3-pole
1 - 75
1

Related parts for 3130-F110-H7T1-W02Q-15A

3130-F110-H7T1-W02Q-15A Summary of contents

Page 1

... Thermal Overcurrent Circuit Breaker 3130 Description Single, two and three pole rocker switch/thermal trip free circuit breakers (S-type TO CBE to EN 60934) of compact design for snap-in panel mounting. Available either with protection on one/both/all poles or, in the case of the double pole version, protection on one pole only. Illumination is optional and there is a choice of rocker colours ...

Page 2

... Switch colour designation opaque 01 black 02 white 04 red 09 green Rocker markings 3130 - N/A for non-illuminated version ** unprotected poles have to ordered with terminal design N7 *** without series resistor and diode selected by customer. Recommendation: 4 0.43 kΩ 10- 1.1 kΩ 20- 2.7 kΩ diode 1N4007 Ordering information - multipole Type No. 3130 ...

Page 3

... Thermal Overcurrent Circuit Breaker 3130 3130-F110-… OFF ON terminal for illumination conductor size 0. (AWG26), length 180 mm (7.09 in.) LINE I.3 I.2 I.I 2 blade terminals DIN 46244-C-Ms-S .079 (QC 2x.110 P7 or N7) 20 .787 Side view 34 1.34 switch only LINE I.I flat head screw M3.5x5 -MS ISO 1580 (H7) tightening torque max ...

Page 4

... Thermal Overcurrent Circuit Breaker 3130 Installation drawing 3130-F1... When installing the circuit breaker apply pressure on bezel only. operating area 1 LINE I.3 I.2 I .315 .197 20 mounting area .787 Typical time/current characteristics Multipole types: all poles symmetrically loaded. With single pole overload, thermal tripping will be at approx. 1. with 2-pole devices and at approx. 1. 0.1 … ...

Related keywords