STBVP6-RB1E02 BANNER ENGINEERING, STBVP6-RB1E02 Datasheet - Page 8

no-image

STBVP6-RB1E02

Manufacturer Part Number
STBVP6-RB1E02
Description
Safety; Duo-Touch; Run Bar System; LED Indicator; 2 NC Safety Contacts
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of STBVP6-RB1E02

Function
Proximity
Primary Type
Photoelectric
Sensing Mode
Through-Beam
Technology
Photoelectric
Connection of STB Touch Buttons
To maintain a Type IIIC / Category 4 hookup, both the normally open and the normally
closed outputs of each STB button must be connected to a two-hand control system or
module (e.g., Banner model AT-FM-10K, AT-..M-13A, AT-..M-11KM or the Banner Safety 
Controller SC22-3) that meets the requirements listed on page 4 and monitors the STB 
outputs such that if they are not in a complementary state (one open/non-conducting and 
one closed/conducting) the system will lock out and prevent further operation until the 
fault is repaired.
The +24V dc supply power for the STB buttons must be the same supply that powers the
two-hand control system or module. If a DUO-TOUCH SG safety module is used, use 
terminals Z1 and Z2 for supply voltage for the STB buttons.  
Figure 6. STB Touch Button block diagram
Connection of Emergency Stop Button
For models with an E-stop button, connection of the E-stop button is made at the screw 
terminals on the contact element mounted on the mounting adapter.
Figure 9. E-stop wiring terminals
DUO-TOUCH
8
P/N 131634 rev. B
V+
Controller
Micro-
1
+
Solid-State
10-30V dc
Screw Terminals
Controller
Micro-
2
®
Run Bar with STB Buttons
V+
Figure 7. Hookup to two STB Touch Buttons
Figure 10. E-stop wiring diagram
+ –
STB2
Logic
with PNP (sourcing) outputs
+ –
STB1
Logic
Brown
Blue
White
Black
White
Black
Contact
Element 1
Contact
Element 2
Z1
Z2
S12
S11
S13
S22
S21
S23
AT-GM-13A
AT-HM-13A
Banner Engineering Corp. • Minneapolis, MN U.S.A.
www.bannerengineering.com  •  Tel: 763.544.3164
Figure 8. Hookup of two STB Touch Buttons
Whenever two or more E-stop switches
are connected to the same E-stop safety
module, the contacts of both switches
must be connected together in series.
This series combination is then wired to
the respective safety module input. Never
connect the contacts of multiple E-stop
switches in parallel to the E-stop safety
module inputs; this defeats the switch
contact monitoring ability of the safety
module, and creates an unsafe condition
which could result in serious injury or death.
Black
+24 V dc
0 V dc
STB1
+24 V dc
to the Banner Safety Controller
White
WARNING . . .
Multiple E-Stop
Switches
S1 S2 S3 S4 S5 S6 S7 S8 S9 S10
A1 A1 A2 A2
Brown
Blue
01 02 03 04 05 06 07
Black
0 V dc
STB2
White
SC22-3

Related parts for STBVP6-RB1E02