53220A Agilent Technologies Test Equipment, 53220A Datasheet - Page 14

no-image

53220A

Manufacturer Part Number
53220A
Description
Universal Frequency Counter/Timer, 350 MHz, 12 digit/sec, 100 ps
Manufacturer
Agilent Technologies Test Equipment
Type
Counter/Timer350 MHz Universal Frequency Counter/Timer, 12 digit/sec, 100 psr
Datasheet

Specifications of 53220A

Frequency Range
DC coupled 1 mHz to 350 MHz; AC coupled 10 Hz to 350 MHz
Input Impedance
Selectable 1 MΩ ±1.5% or 50Ω ±1.5%
Input Type
Front panel BNC
Input, Range
±5 V (± 50 V) full scale ranges
Noise
500 μVrms (max), 350 μVrms (typ)
Number Of Channels
3 channels
Sensitivity
DC - 100 MHz: 20 mVpk > 100 MHz: 40 mVpk
Timebase
Timebase Uncertainty = ( Aging + Temperature + Calibration Uncertainty )
1. All Timebase Aging Errors apply only after an initial 30-days of continuous powered operation and for a constant altitude ±100 m.
2. Only use the Factory Calibration error values for the period before your first re-calibration. Factory Calibration uncertainty includes
3. Warm-up error applies when the instrument is powered on in a stable operating environment.
4. Retrace error may occur whenever the instrument line-power is removed or whenever the instrument is battery operated and the
Aging
Temperature (typ)
Calibration uncertainty
Supplimental characteristics (typ)
After the first 1-year of operation, use ½ x (30-day and 1-year) aging rates shown.
the instrument settability error, the factory calibration source uncertainty, and additional timebase uncertainty due to factory
calibration before the required initial 30-days of powered operation. Settability defines the resolution increments you can reach is in
steps of 0.1 ppb (0.01 ppb on Option 010).
When moved between different operating environments add the Temperature error during the initial 30-minutes of powered operation
battery fully discharges. Retrace error is the residual timebase shift that remains 72-hours after powering-on an instrument that has
experienced a full power-cycle of the timebase. Additional frequency shift errors may occur for instrument exposure to severe
impact shocks >50 g.
24-hour, T
30-day, T
1-year, T
0º C to 55º C relative to 25º C
TCAL ± 5º C
Initial factory calibration
5-min. warm-up error
72-hour retrace error
Allan deviation t = 1s
1
(spec)
CAL
CAL
CAL
Timebase
±5º C
±5º C
±1º C
4
3
2
(typ)
± 0.2 ppm (typ)
± 0.5 ppm
± 0.5 ppm
Standard
< 50 ppb
± 1 ppm
± 1 ppm
± 1 ppm
TCXO
1 ppb
14
Ultra-high stability OCXO
± 0.3 ppb (typ)
Option 010
± 0.5 ppb
± 10 ppb
± 50 ppb
± 50 ppb
± 10 ppb
0.01 ppb
± 5 ppb
< 2 ppb