53220A Agilent Technologies Test Equipment, 53220A Datasheet - Page 11

no-image

53220A

Manufacturer Part Number
53220A
Description
Universal Frequency Counter/Timer, 350 MHz, 12 digit/sec, 100 ps
Manufacturer
Agilent Technologies Test Equipment
Type
Counter/Timer350 MHz Universal Frequency Counter/Timer, 12 digit/sec, 100 psr
Datasheet

Specifications of 53220A

Frequency Range
DC coupled 1 mHz to 350 MHz; AC coupled 10 Hz to 350 MHz
Input Impedance
Selectable 1 MΩ ±1.5% or 50Ω ±1.5%
Input Type
Front panel BNC
Input, Range
±5 V (± 50 V) full scale ranges
Noise
500 μVrms (max), 350 μVrms (typ)
Number Of Channels
3 channels
Sensitivity
DC - 100 MHz: 20 mVpk > 100 MHz: 40 mVpk
Speed Characteristics
1. These Math operations do not apply for Continuous Totalize or Timestamp measurements.
2. Allan Deviation is only calculated for Frequency and Period measurements. Allan Deviation calculation is available on both 53220A
3. Limit Test only displays on instrument front panel. No hardware output signal is available.
4. Operating speeds are for a direct connection to a >2.5 GHz dual core CPU running Windows
5. Throughput data based on 53230A with a 1 µsec gate time. Typical reading throughput assumes ASCII format, Auto level OFF with
6. Maximum 53230A rates represent >= 20 MHz input signals with min gate times, no delays or holdoffs. Measurement rates for the
Measurement/IO timeout
(nom)
Auto-level speed
Configure-change speed
Single measurement
throughput
Block reading throughput
Maximum measurements to internal memory speed
Frequency, period, totalize
Frequency ratio
Time interval, rise/fall,
width, burst width
Duty cycle
Phase
PRI, PRF
Transfer from memory to PC via:
LAN (sockets)
LAN (VXI-11)
USB
GPIB
and 53230A, it is only gap free on 53230A.
a 10/100/1000 LAN interface.
READ? SCPI command. For improved reading throughput you should also consider setting (FORM:DATA REAL,64), (DISP OFF), and set
fastest gate time available.
53210A & 53220A are limited by min gate time. Actual meas rates are limited by the repetition rate of the input being measured.
5
5
4
300 readings/sec
(meas)
53210A
N/A
N/A
N/A
N/A
Optimized (Avg. using *TRG;DATA:REM? 1, WAIT)
Optimized (Avg. using *TRG;DATA:REM? 1, WAIT)
0 s (no timeout or 10 ms to 2000 s, in 1 ms steps)
Frequency, Period, Range, Level: 50 ms (typ)
6
LAN (sockets): 10,500 readings/sec
LAN (sockets): 66,500 readings/sec
LAN (VXI-11): 48,000 readings/sec
LAN (sockets): 210 Readings/sec
LAN (sockets): 350 Readings/sec
LAN (VXI-11): 9,800 readings/sec
LAN (VXI-11): 150 Readings/sec
LAN (VXI-11): 145 Readings/sec
Slow mode (50 Hz): 350 ms (typ)
Fast mode (10 kHz): 10 ms (typ)
Typical (Avg. using READ?):
Typical (Avg. using READ?):
11
GPIB: 17,200 readings/sec
USB: 10,900 readings/sec
USB: 66,500 readings/sec
GPIB: 4,800 readings/sec
GPIB: 240 Readings/sec
GPIB: 400 Readings/sec
USB: 210 Readings/sec
USB: 380 Readings/sec
600,000 readings/sec
150,000 readings/sec
800,000 readings/sec
22,000 readings/sec
1,000 readings/sec
53220A
N/A
®
XP Pro SP3 or better with 4 GB RAM and
75,000 readings/sec
44,000 readings/sec
90,000 readings/sec
48,000 readings/sec
37,000 readings/sec
75,000 readings/sec
53230A