EM32-1B Lascar Electronics, EM32-1B Datasheet - Page 4

no-image

EM32-1B

Manufacturer Part Number
EM32-1B
Description
Voltmeter, LED; Voltmeter Meter Type; LED; 0.31 in.; 5 VDC (Typ.); 0 to degC
Manufacturer
Lascar Electronics
Type
Voltager
Datasheet

Specifications of EM32-1B

Accuracy
±0.1% %
Connection Type
Screw
Cut Out, Panel
1.28"Dia.
Digit Height
0.43
Dimensions
0.93"H×1.5"Dia.
Display Digit Height
0.31 "
Display Type
LCD
Function
Voltage
Meter Type
Voltmeter
Number Of Digits
3-1/2
Primary Type
Electronic
Temperature, Operating
0 to +50 °C
Voltage, Supply
5 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
EM32-1B
Specifications liable to change without prior warning
SCALING
Two resistors Ra and Rb
may be used to alter the
full scale reading (FSR) of
the meter - see table. The
track across Ra must be cut
for on-board scaling. The
meter will have to be re-
calibrated by adjusting the
calibration potentiometer
on the rear of the module.
APPLICATIONS
Do not connect more than one meter to the same power supply if the meters cannot use the same signal
ground. Taking any input beyond the power supply rails will damage the meter.
5V supply operation
Measuring a single ended input
voltage referenced to supply, i.e. the
input voltage and the meter's power
supply share the same 0V rail.
Ensure jumper link J1 is not fitted.
Ensure jumper link J2 is not fitted.
9V supply operation
Measuring a single ended input
voltage referenced to supply, i.e. the
input voltage and the meter's power
supply share the same 0V rail.
Ensure jumper link J1 is not fitted.
Ensure jumper link J2 is fitted.
±200mV
±200mV
+3.75 to +7.0V
+
+
+3.5 to +6.5V
-
-
-3.75 to -7.0V
IHI
IHI
ILO
ILO
V+
0V
V+
0V
(3.5 to 6.5V Meter Power Supply)
(7.5 to 14.0V Meter Power Supply)
0V
*Ensure that Ra is rated for high voltage use.
Must use external scaling resistors (Do not cut track across Ra).
Voltage
Current
Vin
Iin
Measuring an input voltage referenced to
a floating supply, i.e. the input voltage
and the meter's power supply are isolated
from each other.
Ensure jumper link J1 is fitted.
Ensure jumper link J2 is not fitted.
Measuring an input voltage referenced to
a floating supply, i.e. the input voltage
and the meter's power supply are isolated
from each other.
Ensure jumper link J1 is fitted.
Ensure jumper link J2 is not fitted.
±200mV
±200mV
+
+7.5 to +14.0V
+
-
-
+3.5 to +6.5V
2000V*
200mA
200 A
20mA
200V
2mA
20V
FSR
2V
EM32-1B
m
Round Hole Mounting LCD Voltmeter
910k
1M
1M
1M
0R
0R
0R
0R
Ra
IHI
ILO
IHI
ILO
Issue 4
V+
0V
V+
0V
100R
100R
100k
10k
10R
Rb
1R
1k
1k
L1 =
L1 =
0V
0V
November/2006
Vin or in
Measuring a current from a circuit which is
floating with respect to the meter's supply,
i.e. the current and the meter's power
supply are isolated from each other.
Ensure jumper link J1 is fitted.
Ensure jumper link J2 is not fitted.
Measuring a current from a circuit which is
floating with respect to the meter's supply,
i.e. the current and the meter's power
supply are isolated from each other.
Ensure jumper link J1 is fitted.
Ensure jumper link J2 is not fitted.
+
-
I
I-
I
I-
I
+
+
J1
RB
Ra
Rb
Rb
+7.5 to +14.0V
+3.5 to +6.5V
R.C.
RA
Rb
J2
L1
Applies to EM32-1B/2
IHI
ILO
Cut track across Ra
for on-board scaling
EM32-1B
IHI
ILO
IHI
ILO
V+
V+
0V
0V
Page 4 of 4
Page 4 of 4
0V
0V