EMC1500 Lascar Electronics, EMC1500 Datasheet - Page 2

no-image

EMC1500

Manufacturer Part Number
EMC1500
Description
Meter, Hour; Digital; 5 to 27 VDC; Hole
Manufacturer
Lascar Electronics
Type
Totalizerr
Datasheet

Specifications of EMC1500

Accuracy
±2 Sec/24 hrs.
Application
For maintenance or inspection applications
Digit Height
0.5
Dimensions
1.73"W×0.82"H
Display Digit Height
0.35 "
Display Type
LCD
Function
Elapsed Time
Meter Type
Digital
Mounting Type
Hole
Number Of Digits
6
Primary Type
Electronic
Range, Measurement
9999.9 & 99999 hrs.
Special Features
Splashproof
Temperature, Operating
0 to +50 °C
Voltage, Supply
5 to 27 VDC
Lead Free Status / Rohs Status
RoHS Compliant part
TOTAL
WIRE FUNCTIONS
0. Black
1. Brown
2. Red
3. Orange V-SENSE
4. Yellow
5. Green
6. Blue
7. Violet
Warning :
DISPLAY FUNCTIONS
8888.8
TRIP
- - - - - - - - - -
Specifications liable to change without prior warning
APPLICATIONS
0V
RANGE
V+
PULSE
LZB
RESET
TRIP/TOTAL
The 5 digit readout displays elapsed time in hours.
This symbol is displayed when trip mode is selected (see Wire Functions above)
This symbol is displayed when total mode is selected (see Wire Functions above)
The 10-segment incrementing bar indicates that the module is working correctly and counting hours.
Basic 3-wire operation:
Open S1 to read TOTAL value
without counting hours.
9999.9 Hour range
- 99999 Hour range
- Leading Zeros are displayed
- Timing in TOTAL mode
- Leading Zeros are displayed
- Timing in TRIP mode
Do not connect the following wires to V+: RANGE, PULSE, LZB, RESET, TRIP/TOTAL, as this may
damage the meter. The user must incorporate suitable protection circuitry in applications where
the voltage to any of the meter's wires can exceed 27V d.c., including transient conditions, else
damage to the meter may occur. In particular, for applications in harsh electrical environments,
e.g. automotive, suitable external protection must be provided to protect against "load dump"
conditions, transients, etc.
TRIP
Black
-
Orange
TOTAL
Negative power supply connection.
Do not connect for 99999 Hour range.
Connect to 0V for 9999.9 Hour range.
Positive power supply connection.
Connect to V+to start/continue counting elapsed hours.
Connect to 0V or do not connect to read TRIP or TOTAL value without counting elapsed hours.
Normally at 0V, this output goes High (+3.3V) every hour in the selected mode.
Do not connect to display leading zeros.
Connect to 0V to blank all leading zeros.
When reading is 0000.0 or 00000, leading zeros are not blanked.
Connect momentarily to 0V to reset the display to zero (internally connected to V+ via pull-up resistor).
Do not connect for TOTAL mode operation. In TOTAL mode, the elapsed hour meter cannot be reset to zero.
Connect to 0V for TRIP mode operation. In TRIP mode, the elapsed hour meter can be reset to zero.
Red
Black
Brown
0V
-
Red
S1
Hrs
Hrs
Orange
Violet
V+
0V
V+
EMC 1500
Issue 10
Leading zeros blanked.
Close S1 to select TRIP mode.
Using the PULSE O/P to drive an LED.
The LED will illuminate once after every hour.
TRIP
-
IRCN 0539
Orange
Black
Black
Orange
TOTAL
Green
Red
-
Brown
Red
Hrs
Hrs
S1
M.C.
Violet
Violet
V+
0V
Applies to EMC 1500/3
Yellow
No: 716 - Page 2 of 2
R
V+
0V
LED

Related parts for EMC1500