D-A54 SMC Corporation, D-A54 Datasheet - Page 84

no-image

D-A54

Manufacturer Part Number
D-A54
Description
Sensor, reed switch, tie rod mount, grommet connection, for NCA1 cylinder
Manufacturer
SMC Corporation
Datasheet

Specifications of D-A54

Technology
Reed
Plug-in Connector Assembly
D-A73C/A80C, D-J79C
D-C73C/C80C, D-H7C
With the convex port of the connector, insert the connector into the auto
switch into the sleeve. Screw the locking ring onto the switch.
(Do not tighten with pliers.)
Technical Data 1:
Plug-in Connector Assembly/
How to Use DIN Terminal
Locking ring
Connector
Sleeve
How to Use DIN Terminal:
D-A44/A44A/A44C
Connection procedure
1. Loosen the set screw and pull out the connector from the pin plug.
2. Be sure to remove the set screw first and then insert a screwdriver into a
3. Follow the procedures and connect wires securely to specified terminals.
4. In standard cases, crimp-style terminals are used to connect wires.
How to connect
How to change position of electrical entry
After separating the terminal block from the terminal cover, change the
position of the terminal cover to any desired direction (4 directions at every
90°) to change the position of electrical entry.
Caution
When plugging a connector in the pin plug or pulling it out, hold a connector
perpendicularly as much as possible, not to slant it.
Applicable cable (Heavy-duty cord)
Applicable to cable O.D. of ø6.8 to ø11.5.
Applicable crimp-style terminal
1.25Y-3L, 1.25-3.5S, 1.25-4M
recessed groove under the terminal block to separate the terminal cover
from the terminal block.
Please select proper crimp-style terminals so that the wire can be
properly connected to terminal fittings.
Gland gasket
AC:
Connect to terminal no. 1 and no. 2
DC:
Connect (+) to no. 1 terminal and (–) to no. 2 terminal.
Gland washer
Tightening gland
Terminal cover
Terminal thread
Terminal gasket
Terminal block
Fixing screw
6-16-63
CJ1
CJP
CJ2
CM2
CG1
MB
MB1
CA2
CS1
C76
C85
C95
CP95
NCM
NCA
D-
-X
20-
Data