RC82562EP Intel, RC82562EP Datasheet - Page 136

no-image

RC82562EP

Manufacturer Part Number
RC82562EP
Description
IC ETH 10/100 PLC DEV CTRL 64BGA
Manufacturer
Intel
Datasheets

Specifications of RC82562EP

Rohs Status
RoHS non-compliant
Controller Type
Ethernet Controller
Interface
IEEE 802.3
Voltage - Supply
3.135 V ~ 3.465 V
Mounting Type
Surface Mount
Package / Case
64-BGA
Current - Supply
-
Operating Temperature
-
Other names
832361

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
RC82562EP
Manufacturer:
Intel
Quantity:
10 000
Physical Layer Interface
7.4
7.4.1
128
Table 60. LED Switch Control
Auto-Negotiation Functionality
The PHY units of the 8255x devices (excluding the 82557) all support auto-negotiation (N-Way).
Auto-negotiation is an automatic configuration scheme designed to manage interoperability in
heterogeneous LAN environments. It allows two stations with “N” different modes of
communication to establish one common mode of operation. Upon power-up, auto-negotiation
establishes a link using one or more devices capable of auto-negotiating. An hub that supports
auto-negotiation can detect and automatically configure its ports to take maximum advantage of
common modes of operation without user intervention or prior knowledge by either station. The
possible common modes of operation are: 100BASE-TX, 100BASE-TX full duplex, 10BASE-T,
and 10BASE-T full duplex.
Description
Auto-Negotiation selects the fastest operating mode (in other words, the highest common
technology denominator) available to hardware at both ends of the cable. A PHY’s capability is
encoded by bursts of link pulses called Fast Link Pulses (FLPs). Connection is established by FLP
exchange and handshake during initialization time. Once the link is established by this handshake,
the native link pulse scheme resumes (for example, 10BASE-T or 100BASE-TX). If only one end
of the twisted pair is auto-negotiation capable, then the FLP exchange fails and another scheme
called parallel detection is used to determine the link settings. A PHY reset, or management
renegotiate command (through the MDI interface), restarts the auto-negotiation process. To enable
auto-negotiation, bit 12 of the MDI Control Register must be set. If the PHY cannot perform auto-
negotiation, this bit is set to 0.
Since only one technology can be used at a time (after every renegotiate command), a prioritization
scheme must be used to ensure that the highest common denominator ability is chosen.
lists the technology ability field bit assignments. Each bit in this table is set according to the PHY
capability.
Bits
2:0
000
001
010
011
100
101
110
111
ACTLED# Pin
Activity
Speed
Speed
Activity
Off
Off
On
On
Table 62
10/100 Mbps Ethernet Controller Family Open Source Software Developer Manual
lists the priority of each of the technologies.
LILED# Pin
Link
Collision
Link
Collision
Off
On
Off
On
Table 61