TMC2072-MT SMSC, TMC2072-MT Datasheet - Page 65

no-image

TMC2072-MT

Manufacturer Part Number
TMC2072-MT
Description
IC CTRLR CIRC 100-TQFP DUAL MODE
Manufacturer
SMSC
Series
CircLink™r
Datasheet

Specifications of TMC2072-MT

Controller Type
I/O Controller
Interface
Transceiver
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
40mA
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Package / Case
100-TQFP, 100-VQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
638-1023

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TMC2072-MT
Manufacturer:
Microchip Technology
Quantity:
10 000
Peripheral Mode CircLink™ Controller
Datasheet
3.2.2
SMSC TMC2072
COMR1 Register: Diagnostic/Command Register
- When reading: ARCNET diagnostic register
MY-RECON (bit 7)
When this bit is 1, it indicates that the local reconfiguration timer has timed out. This timeout sends a
reconfiguration burst signal. It is read after an interrupt has been generated by setting RECON bit = 1.
(RECON bit = 1 is set after MY-RECON bit is set to 1.) The bit is cleared by software reset or by being
read.
DUPID (bit 6)
When this bit is 1 in the offline state (TXEN = 0), it indicates that a duplicate node ID exists on the network.
In this state, the network cannot be accessed (TXEN = 1). Check that all the node ID settings are correct.
In the online state (TXEN = 1), this bit is set to 1 every time a token addressed to it is received**. This bit is
cleared by a software reset or by being read.
** Disregard this first setting of DUPID=0 -> 1. The second setting indicates a token addressed to its own
CircLink.
RCVACT (bit 5)
When this bit is 1, it indicates that activity has been detected at the CircLink receive input. This bit is
cleared by a software reset or by being read.
TOKEN (bit 4)
When this bit is 1, it indicates that a token signal on the network has been detected. Note that the token
signal sent by this bit cannot be detected. This bit is cleared by a software reset or by being read.
*1 Not equivalent to the ARCNET original specifications.
*1
COMR1
[READ]
COMR1
[WRITE]
15-8
15-8
7-0
bit
bit
7
6
5
4
3
2
1
0
(Diagnostic Register)
name
--------
MY-RECON
DUPID
RCVACT
TOKEN
EXCNAK
TENTID
NXTIDERR
--------
(Command Register)
name
--------
D7-0
DATASHEET
init. value
init. value
--
--
0
0
0
0
0
0
0
0
0
Page 65
Description
reserved (all "0")
My Reconfiguration
Duplicate ID
Receive Activity
Token Seen
Excessive NAK
Tentative ID
New Next ID
Reserved
Description
Reserved (all "0")
D7-0
address:02h
address:02h
Revision 0.1 (06-07-07)

Related parts for TMC2072-MT