TLE7263E Infineon Technologies, TLE7263E Datasheet - Page 11

no-image

TLE7263E

Manufacturer Part Number
TLE7263E
Description
IC SYSTEM BASIS CHIP DSO-36
Manufacturer
Infineon Technologies
Datasheet

Specifications of TLE7263E

Controller Type
System Basis Chip
Interface
SPI
Voltage - Supply
13.5V
Current - Supply
1mA
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
DSO-36
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
SP000075929
TLE7263E
TLE7263EINTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE7263E
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
4.2
In order to reduce the current consumption to a minimum, the SBC offers a Sleep Mode
without Cyclic Sense (see
off the integrated bus transceivers and respective termination, main voltage regulator as
well as the High-Side switch. Upon a voltage level change at the monitoring/wake-up
pins or by a CAN or LIN message the SBC Sleep Mode will be terminated and the SBC
Standby Mode will automatically be entered.
Figure 4
Note: To switch into Low Power Mode from Standby Mode the device should be
Data Sheet
switched into Normal Mode first. This is required to reset the CAN and LIN
transceiver to ensure correct wakeup as well as to ensure the correct function of
the RO pin when going to Sleep Mode. The time the device is in Normal Mode
before going to Low Power Mode should be long enough that the Vcc2 is up. This
can be released by a wait time or by reading the status of Vcc2 via SPI (bit13).
MS2
0
SBC Sleep Mode without Cyclic Sense
SBC Active Mode
MS1
0 / 1
State Diagram “SBC Sleep Mode without Cyclic Sense”
0 / 1
MS0
µController SPI-Command:
- disable „cyclic sense function“ via SPI Timing Bits
- select SBC Sleep Mode via SPI Mode Bits
- window watchdog activation / deactivation via SPI
[can remain active as periodic reset timer]
Vcc1
ON
MS2
Figure
1
SBC Sleep Mode
HS-Switch = OFF
MONx inputs
Initialization of
MS1
0
4). This mode is entered via SPI command, and turns-
MS0
0
1)
Vcc1
OFF
11
SBC Standby Mode
Vcc1
ON
transition caused by:
- event at MONx inputs
- CAN message
- LIN message
[SPI indicates source]
switched into SBC Standby mode
1)
if initialization fails, device is
Rev. 1.51, 2007-06-22
sleep_TLE7263
Power Up
Start Up
TLE 7263E
Features