MAP55-4002 POWER ONE, MAP55-4002 Datasheet - Page 2

no-image

MAP55-4002

Manufacturer Part Number
MAP55-4002
Description
Linear & Switching Power Supplies Book as (MAPxx-xxxx)
Manufacturer
POWER ONE
Type
Commercial, Industrialr
Datasheet

Specifications of MAP55-4002

Brand/series
MAP55 Series
Configuration
Open-Frame
Current, Input
1.6 A (RMS) @ 90 VAC
Current, Leakage
500 μA (Max.)
Dimensions
6 in. L x 3.27 in. W
Hold Time
20 mS (Min.)
Mounting Type
Panel
Number Of Outputs
4
Operation
Switching
Output
-12 VDC @ 0.5 A, +5 VDC @ 6 A, +12 VDC @ 0.5 A, +12 VDC @ 3 A
Power, Output
55 W
Power, Rating
55 W (Continuous)
Primary Type
AC-DC
Temperature, Operating
50 °C
Voltage, Input
110/220 VAC
Voltage, Output
-12, +5, +12, +12 VDC
Voltage, Output 1
5 V
Voltage, Output 2
-5 V
Voltage, Output 3
12 V
Voltage, Output 4
-12 V
En61000-4-2 Esd Level 4 (8 Kv)
All Map Products
En61000-4-3 Radiated Level 3 (10 V/m)
All Map Products
Universal Input
90-132 VAC or 175-264 VAC
Output Current (max)
6/3/0.5/0.5A
Input Voltage
90 to 132/175 to 264V
Output Voltage
5/12/-12/12V
Output Power (max)
55W
Input Frequency
47 to 63Hz
Efficiency
73%
Screening Level
Commercial
Product Length (mm)
83.1mm
Product Height (mm)
40.6mm
Product Depth (mm)
152.4mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
70C
Mounting Style
Screw
Pin Count
11
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date
manufactured. Specifications are subject to change without notice.
JUL 14, 2006 revised to AUG 10, 2006
Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
Output Specifications
PARAMETER
Efficiency
Minimum Loads
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
NOTES:
Interface Signals and Internal Protection
PARAMETER
Overvoltage Protection
Overload Protection
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand
Voltage
Electromagnetic
Interference,
Conducted
Insulation Resistance
Leakage Current
1) Nominal rise time for MAP55-1024 is 36 msec.
CONDITIONS/DESCRIPTION
Continuous input range.
AC input.
Lowest AC input voltage that regulation is maintained with full rated loads.
Nominal AC Input Voltage (115VAC), full rated load.
90 VAC (55W load).
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 264VAC (one cycle). 25° C.
Switching frequency of power supply (varies with load).
CONDITIONS/DESCRIPTION
Full load, 115VAC. Varies with distribution of loads among outputs.
MAP55-1012
MAP55-1024
MAP40-1005 and all multiple output models, main channel only.
Full load, 20MHz bandwidth.
Continuous output power, all multiple output models.
Peak output power (60s maximum, 10% duty cycle), all multiple output models.
Output voltage overshoot/undershoot at turn-on, V1, V2.
Varies by output. Total regulation includes: line changes from 90-132 VAC or 175-264 VAC,
changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output of multiple output units).
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90% (Note 1).
CONDITIONS/DESCRIPTION
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 No. 234/950.
EN60950 (TUV).
Input to output.
FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
Input to output.
Per EN60950, 264VAC.
Main output only of multiple output units.
Page 2 of 3
MAP55 AC-DC Series Data Sheet
MAP40-1005
MAP55-1012
MAP55-1024
2600
0.21
0.11
0.50
17.5
32.0
175
MIN
MIN
MIN
MIN
5.5
5.6
90
47
90
20
22
73
B
B
A
1
7
NOM
NOM
NOM
NOM
1.6
See Model Selection Chart.
7
See Model Selection Chart.
www.power-one.com
Approved.
19.7
36.0
MAX
132
264
180
MAX
500
MAX
MAX
500
6.8
6.8
63
38
55
65
1
4
Amps
Watts
Watts
UNITS
A
UNITS
UNITS
UNITS
Class
VDC
VAC
VAC
A
kHz
Sec
ms
ms
µA
Hz
μs
RMS
%
%
V
PK

Related parts for MAP55-4002