LPS175-M Emerson Network Power, LPS175-M Datasheet - Page 2

no-image

LPS175-M

Manufacturer Part Number
LPS175-M
Description
Linear & Switching Power Supplies 24v(24-54v) o/p 175W 4.25 x8.5 Medical
Manufacturer
Emerson Network Power
Type
Open Framer
Datasheet

Specifications of LPS175-M

Output Current (max)
7.5A
Input Voltage
85 to 264V
Output Voltage
24V
Number Of Outputs
1
Input Frequency
47 to 63Hz
Efficiency
75%
Screening Level
Commercial
Product Height (mm)
38.1mm
Product Depth (mm)
108mm
Operating Temperature Min Deg. C
0C
Operating Temperature Max Deg. C
50C
Pin Count
15
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LPS175-M
Manufacturer:
ASTEC
Quantity:
1 000
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02”.
3. Specifications are for convection rating at factory settings unless
otherwise stated.
4. Mounting screw maximum insertion depth is 0.12”.
5. Warranty: 2 year
6. Weight: 1.8 lb / 0.85 kg
Environmental Specifications
Logic Control
Power failure:
Remote inhibit:
Remote sense:
DC - OK:
Ordering Information
LPS172-M 5 V (2.5 - 6 V)
LPS173-M 12 V (6 - 12 V)
LPS174-M 15 V (12 - 24 V)
LPS175-M 24 V (24 - 54 V)
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25 °C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load
4. Remote inhibit resets OVP latch.
Note: -C suffix added to the model number indicates cover option.
Operating temperature:
Low temperature start:
Temperature coefficient: ±0.4% per °C
Storage temperature:
Electromagnetic
susceptibility:
Humidity:
Vibration:
MTBF demonstrated:
Number
Model
ranges.
Voltage
Output
0 A
0 A
0A
0A
Minimum
T TL logic signal goes high 100 - 500 msec after V1 output; It goes low
at least 4 msec before loss of regulation
Requires contact closure to inhibit outputs
C ompensates for 0.5 V lead drop min. Will operate without remote
sense connected. Reverse connection protected.
TTL logic signal goes high after main output is in regulation. It goes
low when there is a loss of regulation
Load
0° to 50 °C ambient;
derate each output at 2.5% per degree from 50° to 70 °C
-20 °C
-40° to 85 °C
Designed to meet IEC EN61000-4, -2, -3, -4, -5, -6, -8, -11 Level 3
Operating; non-condensing 5% to 95%
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at four
major resonances 0.75G peak 5Hz to 500Hz, operational
>550,000 hours at full load and 25 °C ambient conditions
22 A
9.1 A
7.3 A
4.5 A
Maximum Load with
Convection Cooling
35 A
15 A
12 A
7.5 A
Maximum Load
with 30CFM
forced Air
38 A
16.5 A
13.2 A
8.2 A
Peak Load 1 Regulation 2
±2%
±2%
±2%
±2%
50 mV
120 mV
<1%
<1%
Ripple P/P
(PARD) 3
Mating Connectors
AC Input (SK4):
DC Outputs (SK3): Molex 19141-0058
Control Signals
(SK1):
Emerson Network Power Connector Kit #70-841-016
Pin Assignments
Connector LPS17x
SK1
SK2
SK3
Embedded Power for
Business-Critical Continuity
PIN 1
PIN 2
Pin 3
Pin 4
PIN 5
PIN 6
PIN 7
PIN 8
PIN 9
PIN 10
TB-1
TB-2
PIN 1
PIN 2
Pin 5
Molex 09-50-8051 (USA)
Molex 09-91-0500 (UK)
PINS: 08-58-0111
Molex 90142-0010 (USA)
PINS: 90119-2110 or
Amp: 87977-3
PINS: 87309-8
+12 V
5 V Standby
Common
V1 SWP
Common
+V1 sense
Sense common
Remote inhibit
DC poer good
POK
COMMON
Main output
GROUND
LINE
NEUTRAL
Rev. 12.08.08_113
LPS170-M Series
2 of 3

Related parts for LPS175-M