FXP1800-48G POWER ONE, FXP1800-48G Datasheet - Page 6

no-image

FXP1800-48G

Manufacturer Part Number
FXP1800-48G
Description
Linear & Switching Power Supplies Front End 1800W (48V)
Manufacturer
POWER ONE
Datasheets

Specifications of FXP1800-48G

Product
Switching
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Protection
Control
Specification is valid for input voltage, load, and temperature ranges, unless otherwise stated.
DEC 12, 2006 revised to FEB 22, 2007
1
1
Input fuse
Inrush current limitation
Output
Overvoltage protection latching
Overtemperature protection
Provided over the I
Status Indication
I
PS present pin
PS remote shutdown / Inhibit pin
Power supply OK (I
DC current fail (I
AC fail / Power down warning
(I
DC fail / Output voltage fault
(I
Temperature warning (I
DC voltage monitoring (I
DC current monitoring (I
DC voltage trimming
(I
Fan OK (I
Synch. startup pin
For detailed Information on I
document.
Remove input voltage to reset.
Fan speed control (I
2
C digital bus
2
2
2
C & OC)*
C & OC)*
C or external resistor)
2
C & OC)
Parameter
Parameter
2
C)*
2
1
C interface or as an open collector signal on the output connector (OC).
2
2
C)*
C)
2
1
1
C & OC)
2
2
C)
C)
1
1
2
C, please see document “FNP1500-I2C-controlling.pdf” or use the Power-One I
1
1
Internal undervoltage and overvoltage supervision of V
mA pull-down capability, referenced to logic return (LRTN). DC fail will go high or open if
V
the front panel indicates normal operation. The LED will flash if in parallel operation V
ok, but the unit is disabled.
Overcurrent signal which can be used for synchronous startup of units in parallel or to
recover from an overload condition. (See application note).
LEDs: DC OK (green), AC OK (green); fan fail and overtemperature (amber)
Contact closure to logic ground ( internal pull-down resistor of 1 kΩ)
TTL compatible signal, inhibited when open contact, high or at TTL logic “1”
Signal referenced to logic return (LRTN)
AC OK & DC OK & no overcurrent & no overtemperature & fans working
Overcurrent on I
Provides a warning that the input power has failed at least 5 ms before the
output falls out of regulation (<90% V
Open collector signal with 20 mA pull-down capability, referenced to logic
return (LRTN). AC fail will go high or open during power fail condition
and will go low when input is within the operating range. A Power Fail
warning will turn off the green AC OK LED.
I
has reached [T
I
shutdown. Open collector signal with 20 mA pull-down capability, referenced
to logic return (LRTN). The OC-output will go low 100 ms before an over-
temperature condition shuts down the unit. An amber LED on the front panel
indicates overtemperature or fan fail.
Monitors the voltage V
Accuracy ± 0.45 V over setting range, temperature and load.
Monitors the output current I
Output voltage trimming V
Setting accuracy over I
Two fan speed levels automatically set depending on the internal temperature.
The fan speed can be set to full speed or automatic control.
Indicates if the fans are operating or have failed.
Monitors alarm functions and sets parameters
2
2
Automatic power shutdown at T
o1
C critical temperature warning: Indicates that the operating temperature
C & OC overtemperature warning: Indicates if the unit is in overtemperature
is < 90% or > 110% of V
Conditions/Description
& FNR-3 and FXR-3 Power Shelves Data Sheet
Not user accessible
FNP1500/1800 and FXP1500/1800 Front-Ends
Absolute
Tracking
Page 6 of 15
shut-down
o1
– 10K]
o1
2
C: ± 50mV at Vo nom, ± 150 mV over setting range
at the output connector.
o1
: ± 8 % of V
o1
o1 set
: Accuracy ± 0.4A over the load range.
Conditions/Description
, measured in front of the ORing FETs. A green LED on
C
o1 set
o set
).
No-load -, short circuit - and overload proof
Min
115
o1
. Open collector signal with 20
25A, fast blow
With NTCs
Nom
95
2
C Management Interface
www.power-one.com
Max
122
59.5
% V
Unit
°C
V
o1
o nom
is