PKM4618API Ericsson Power Modules, PKM4618API Datasheet - Page 23

no-image

PKM4618API

Manufacturer Part Number
PKM4618API
Description
DC/DC Converters & Regulators 1.8 Vdc 35A Iso Input 36-75V 63W
Manufacturer
Ericsson Power Modules
Series
PKMr
Datasheet

Specifications of PKM4618API

Product
Isolated
Output Power
30 W
Input Voltage Range
36 V to 75 V
Number Of Outputs
1
Output Voltage (channel 1)
1.5 V
Output Current (channel 1)
20 A
Isolation Voltage
1.5 KV
Package / Case Size
Quarter Brick
Output Type
Isolated
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PKM4618API
Manufacturer:
ERICSSON
Quantity:
560
Part Number:
PKM4618API
Manufacturer:
ERICSSON/爱立信
Quantity:
20 000
2.5V/30A Electrical Specification
T
Typical values given at: T
Characteristics
V
V
V
C
P
SVR
η
P
P
P
f
V
V
V
t
t
t
t
t
I
I
I
V
OVP
Note 1: Output filter according to Ripple & Noise section
Note 2: See Operating Information section.
Prepared (also subject responsible if other)
SEC/D/ESECZHW
Approved
SEC/D (Linda Zhong)
PKM 4000 PI series
DC/DC converters, Input 36-75 V, Output 35 A/126 W
O
lim
sc
s
tr
r
s
f
RC
ref
I
Ioff
Ion
O
d
li
RC
Oi
O
tr
Oac
I
= -40 to +100ºC, V
Input voltage range
Turn-off input voltage
Turn-on input voltage
Internal input capacitance
Output power
Supply voltage rejection (ac)
Efficiency
Power Dissipation
Input idling power
Input standby power
Switching frequency
Output voltage initial setting and
accuracy
Output adjust range
Output voltage tolerance band
Idling voltage
Line regulation
Load regulation
Load transient
voltage deviation
Load transient recovery time
Ramp-up time
(from 10−90 % of V
Start-up time
(from V
Vin shutdown fall time
(from V
RC start-up time
RC shutdown fall time
(from RC off to 10% of V
Output current
Current limit threshold
Short circuit current
Output ripple & noise
Over voltage protection
I
I
off to 10% of V
connection to 90% of V
I
= 36 to 75 V, sense pins connected to output pins unless otherwise specified under Conditions.
Oi
)
ref
O
)
O
= +25°C, V
)
Oi
)
I
Conditions
Decreasing input voltage
Increasing input voltage
f = 100 Hz sinewave, 1 Vp-p
50 % of max I
max I
50 % of max I
max I
max I
I
V
0-100% of max I
T
See operating information
0-100% of max I
I
max I
V
V
max I
10-100% of max I
max I
I
max I
max I
I
Vo=0.96Vnom,T
T
max I
T
max I
= 53 V, max I
Output voltage initial setting
O
O
O
O
I
ref
I
I
ref
ref
= 0, V
= 53 V, Load step 25-75-25 % of
= 0 A
= 0 A
= 0 A
= 53 V (turned off with RC)
= 53 V, 0-100% of max I
= +25°C, V
= 25ºC, see Note 2
= +25°C, V
O
O
O
O
O
O
O
O
O
O
, di/dt = 1 A/
, V
, V
I
= 53 V
Oi
I
Checked
MICJOHN
, see Note 1
= 48 V
O
O
I
I
O
= 53 V, 0-100% of
= 53 V, max I
, V
ref
O
O
, unless otherwise specified under Conditions.
O
I
< max T
μ
= 48 V
s,
ref
O
PRODUCT SPECIFICATION
No.
2/1301-BMR631
Date
2006-10-22
O
2.45
min
2.0
2.4
3.2
36
31
31
0
Technical Specifi cation
EN/LZT 146 310 R1B Nov 2006
© Ericsson Power Modules AB
Rev
C
±150
89.7
89.3
90.3
89.3
2.50
2.50
TBD
TBD
200
100
N/A
N/A
N/A
N/A
typ
1.5
9.0
2.6
0.4
3.7
33
34
53
25
36
38
60
3
3
Reference
max
2.55
2.75
100
4.6
0.6
2.6
4.2
75
36
75
10
10
40
30
39
40
PKM 4719A PI
20 (41)
mVp-p
Unit
kHz
mV
mV
mV
ms
ms
ms
ms
dB
m
μ
%
W
W
μs
W
W
V
V
V
V
V
V
V
A
A
A
V
s
s
F
23
s

Related parts for PKM4618API