CY7C65620-56LTXC Cypress Semiconductor Corp, CY7C65620-56LTXC Datasheet - Page 14

IC USB HUB CTLR 2PORT 56VQFN

CY7C65620-56LTXC

Manufacturer Part Number
CY7C65620-56LTXC
Description
IC USB HUB CTLR 2PORT 56VQFN
Manufacturer
Cypress Semiconductor Corp
Series
EZ-USB HX2LP™r
Type
USB Hub Controllerr
Datasheet

Specifications of CY7C65620-56LTXC

Package / Case
56-VQFN Exposed Pad, 56-HVQFN, 56-SQFN, 56-DHVQFN
Controller Type
USB 2.0 Hub Controller
Interface
USB/Serial
Voltage - Supply
3.15 V ~ 3.45 V
Operating Temperature
0°C ~ 70°C
Mounting Type
Surface Mount
Current - Supply
231mA
Mounting Style
SMD/SMT
Operating Temperature Range
0 C to + 70 C
Supply Current
86 mA
Operating Supply Voltage
3.3 V
Rohs Compliant
YES
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
CY4606 - KIT EZ-USB HX2LP 4PORT HUBCY4605 - KIT EZ-USB HX2LP 2PORT HUB
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
428-2930

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CY7C65620-56LTXC
Manufacturer:
CONEXANT
Quantity:
326
Part Number:
CY7C65620-56LTXC
Manufacturer:
CYPRESS
Quantity:
240
Part Number:
CY7C65620-56LTXC
Manufacturer:
CYPRESS/赛普拉斯
Quantity:
20 000
Part Number:
CY7C65620-56LTXCT
Manufacturer:
CYPRESS/赛普拉斯
Quantity:
20 000
Byte 7: EnabledOvercurrentTimer[3:0], DisabledOvercur-
Byte 8: MaximumPower (Full speed)
Byte 9: MaximumPower (High speed)
Byte 10: Reserved
Byte 11: Reserved
Byte 12: HubControllerPower (Full speed, bus powered)
Byte 13: HubControllerPower (High speed, bus powered)
Byte 14: HubControllerPower (Full speed, self powered)
Byte 15: HubControllerPower (High speed, self powered)
Byte 16: PowerOnTimer
Byte 17: IllegalHubDescriptor, CompoundDevice, Full
SpeedOnly, NoPortIndicators, Reserved, GangPowered,
Reserved
Document Number: 38-08037 Rev. *L
Count time in ms for filtering overcurrent detection. Bits 7–4
are for an enabled port, and bits 3–0 are for a disabled port.
Both range from 0 ms to 15 ms. See section
on page 4. Default: 8 ms = 0x88.
This value is reported in the ConfigurationDescriptor:bMax-
Power field and is the current in 2 mA increments that is re-
quired from the upstream hub when connected at full speed.
Default: 0x28 = 80 mA for full speed.
This value is reported in the ConfigurationDescriptor:bMax-
Power field and is the current in 2 mA increments that is re-
quired from the upstream hub when connected at high speed.
Default: 0x57 = 174 mA for high speed.
Write zeros to this location.
Write zeros to this location.
This value is reported in the HubDescriptor:bHubContrCur-
rent field and is the current in milliamperes required by the
hub controller when connected on the upstream hub as a full
speed. Default: 0x50 = 80 mA for full speed.
This value is reported in the HubDescriptor:bHubContrCur-
rent field and is the current in milliamperes required by the
hub controller when connected on the upstream hub as a high
speed. Default: 0xAE = 174 mA for high speed.
This value is reported in the HubDescriptor:bHubContrCur-
rent field and is the current in milliamperes required by the
hub controller when connected on the upstream hub as a full
speed. Default: 0x50 = 80 mA for full speed.
This value is reported in the HubDescriptor:bHubContrCur-
rent field and is the current in milliamperes required by the
hub controller when connected on the upstream hub as a high
speed. Default: 0x64 = 100 mA for high speed.
This
bPwrOn2PwrGood field and is the time in 2 ms increments
from the SetPortPower command until the power on the cor-
responding downstream port is good. Default: 0x32 = 100 ms.
Bit 7: IllegalHubDescriptor. For GetHubDescriptor request,
some USB hosts use a DescriptorTypeof 0x00 instead of
HUB_DESCRIPTOR, 0x29. According to the USB 2.0 stan-
dard, a hub must treat this as a Request Error, and STALL the
transaction accordingly (USB 2.0, 11.24.2.5). For systems
rentTimer[3:0]
value
is
reported
in
the
HubDescriptor:
Port Indicators
Byte 18: AmberPolarity, GreenPolarity, SelfPowerable,
ModulateIndicators, PowerControlPolarity, OverCurrentPo-
larity, OverCurrentMode1, OverCurrentMode2
Byte 19: Write Protect
Byte 20: NumLangs
that do not accept this, the IllegalHubDescriptor configuration
bit may be set to allow CY7C656xx to accept a Descriptor-
Type of 0x00 for this command. Default set to 1.
Bit 6: CompoundDevice. Indicates whether the hub is part of
a compound device. This is reported in the HubDescriptor,
wHub-Characteristics: b2. Default is set to ’0’.
Bit 5: Fullspeed. Only configures the hub to be a full speed
only device. Default is set to ’0’.
Bit 4: NoPortIndicators. Turns off the port indicators and does
not report them as present in the HubDescriptor, wHubChar-
acteristics b7 field. Default is set to ’0’.
Bit 3: Reserved. Set this bit to ‘0’.
Bit 2: GangPowered. Indicates whether the port power
switching is ganged (set to 1) or per-port (set to ’0’). This is
reported in the HubDescriptor, wHubCharacteristics field, b4,
b3, b1, and b0. Default is set to ’0’.
Bit 1: Reserved. Default is set to ’0’.
Bit 0: Reserved. Default is set to ’0’.
Bit 7: AmberPolarity. Indicates the polarity of the amber indi-
cator control. (1 = high, 0 = low)
Bit 6: GreenPolarity. Indicates the polarity of the green indica-
tor control. (1 = high, 0 = low)
Bit 5: SelfPowerable. Indicates whether the hub is capable of
operating in self powered mode. If ‘0’, the hub is capable of
bus powered operation only.
Bit 4: ModulateIndicators. If this bit is set, the indicator outputs
are modulated by a square wave of 120 Hz, for power sav-
ings. If ‘0’, the outputs are static.
Bit 3: PowerControlPolarity. If set, the power control outputs
are active HIGH. If not set, the power control outputs are ac-
tive LOW.
Bit 2: OverCurrentPolarity. If set, the overcurrent inputs are
active HIGH. If not set, the overcurrent inputs are active LOW.
Bit 1: OverCurrentMode1. Reported as bit 4 of the wHubChar-
acteristics field of the hub descriptor. If set to ‘1’, this bit dis-
ables overcurrent detection.
Bit 0: OverCurrentMode2. Reported as bit 3 of the wHubChar-
acteristics field of the hub descriptor. If Bit 1 of this byte is set
to ‘0’, overcurrent detection is enabled. If this bit (Bit 0) is set
to ‘1’, the hub reports overcurrent on a per-port basis. If set to
‘0’, the hub reports overcurrent as the summation of all ports’
current draw.
Writing the value 0x42 to this field enables Write Protect and
any future writes to the EEPROM will fail. Default is set to ‘0’.
Number of supported string languages. CY7C656xx supports
a maximum of 31 languages; if this field is set to ’0’ or a num-
ber larger than 31, all string support is disabled.
CY7C656xx
Page 14 of 25
[+] Feedback