SA56004HDP-T NXP Semiconductors, SA56004HDP-T Datasheet - Page 18

Board Mount Temperature Sensors I2C LOC +/- 2OC AND REM +/- 1OC TS

SA56004HDP-T

Manufacturer Part Number
SA56004HDP-T
Description
Board Mount Temperature Sensors I2C LOC +/- 2OC AND REM +/- 1OC TS
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SA56004HDP-T

Full Temp Accuracy
+/- 1 C, +/- 3 C
Package / Case
SOT-505
Digital Output - Bus Interface
I2C
Digital Output - Number Of Bits
11 bit
Maximum Operating Temperature
+ 125 C
Minimum Operating Temperature
- 40 C
Output Type
Digital
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
SA56004HDP,118
NXP Semiconductors
SA56004X_5
Product data sheet
7.10 SMBus interface
LOW. Furthermore, if the Remote HIGH Setpoint High Byte (RHSHB) register is set to a
value less than +127 C and the Alert Mask is disabled, then the ALERT output will be
pulled LOW. Note that the OPEN bit itself will not trigger an ALERT.
When the D+ pin is shorted to ground or to D , the Remote Temperature High Byte
(RTHB) register is loaded with 128 C (1000 0000) and the OPEN (bit 2 in the Status
register) will not be set. Since operating the SA56004X is beyond its normal limits, this
temperature reading represents this shorted fault condition. If the value in the Remote
Low Setpoint High Byte (RLSHB) register is more than 128 C and the Alert Mask is
disabled, the ALERT output will be pulled LOW.
The device can communicate over a standard two-wire serial interface System
Management Bus (SMBus) or compatible I
employs four standard SMBus protocols: Write Byte, Read Byte, Receive Byte, and
Send Byte. Data formats of four protocols are shown in
of protocol are important:
The SMBus master initiates data transfer by establishing a START condition (S) and
terminates data transfer by generating a STOP condition (P).
Data is sent over the serial bus in sequences of 9 clock pulses according to each 8-bit
data byte followed by 1-bit status of device acknowledgement (A).
The 7-bit slave address is equivalent to factory-programmed address of the device.
The command byte is equivalent to the address of the selected device register.
The Receive Byte format is used for quicker transfer data from a device reading
register that was previously selected.
Rev. 05 — 22 May 2008
Digital temperature sensor with overtemperature alarms
2
C-bus using SCLK and SDATA. The device
Figure
9. The following key points
SA56004X
© NXP B.V. 2008. All rights reserved.
18 of 36

Related parts for SA56004HDP-T