EMC1402-4-ACZL-TR SMSC, EMC1402-4-ACZL-TR Datasheet - Page 16

no-image

EMC1402-4-ACZL-TR

Manufacturer Part Number
EMC1402-4-ACZL-TR
Description
Board Mount Temperature Sensors Dual Temp Snsr
Manufacturer
SMSC
Datasheet

Specifications of EMC1402-4-ACZL-TR

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Revision 1.36 (07-02-09)
5.1.1
5.1.2
5.2
CONVERSION RATE
4 / sec (default)
1 / 16 sec
1 / 8 sec
1 / 4 sec
1 / 2 sec
16 / sec
32 / sec
64 / sec
1 / sec
2 / sec
8 / sec
Conversion Rates
The EMC1402 may be configured for different conversion rates based on the system requirements.
The conversion rate is configured as described in
conversions per second. Other available conversion rates are shown in
Dynamic Averaging
Dynamic averaging causes the EMC1402 to measure the external diode channels for an extended time
based on the selected conversion rate. This functionality can be disabled for increased power savings
at the lower conversion rates (see
automatically adjust the sampling and measurement time for the external diode channels. This allows
the device to average 2x or 16x longer than the normal 11 bit operation (nominally 21ms per channel)
while still maintaining the selected conversion rate. The benefits of dynamic averaging are improved
noise rejection due to the longer integration time as well as less random variation of the temperature
measurement.
When enabled, the dynamic averaging applies when a one-shot command is issued. The device will
perform the desired averaging during the one-shot operation according to the selected conversion rate.
When enabled, the dynamic averaging will affect the average supply current based on the chosen
conversion rate as shown in
The THERM output is asserted independently of the ALERT output and cannot be masked. Whenever
any of the measured temperatures exceed the user programmed THERM Limit values for the
programmed number of consecutive measurements, the THERM output is asserted. Once it has been
asserted, it will remain asserted until all measured temperatures drop below the THERM Limit minus
the THERM Hysteresis (also programmable).
THERM Output
Table 5.1 Supply Current vs. Conversion Rate for EMC1402
(DEFAULT)
ENABLED
AVERAGE SUPPLY CURRENT
1010uA
1020uA
1050uA
1100uA
660uA
660uA
660uA
660uA
660uA
930uA
950uA
Table 5.1
DATASHEET
Section
for the EMC1402
16
6.4). When dynamic averaging is enabled, the device will
DISABLED
1050uA
1100uA
430uA
430uA
475uA
510uA
630uA
775uA
430uA
430uA
430uA
Section
.
1°C Temperature Sensor with Beta Compensation
6.5. The default conversion rate is 4
AVERAGING FACTOR (BASED ON
(DEFAULT)
ENABLED
0.5x
16x
16x
16x
16x
16x
16x
11-BIT OPERATION)
8x
4x
2x
1x
Table
6.6.
SMSC EMC1402
DISABLED
0.5x
1x
1x
1x
1x
1x
1x
1x
1x
1x
1x
Datasheet