E49-DD5 Omron, E49-DD5 Datasheet - Page 10

no-image

E49-DD5

Manufacturer Part Number
E49-DD5
Description
Sensor Hardware & Accessories E4DA 5M EXT. CABLE
Manufacturer
Omron
Datasheet

Specifications of E49-DD5

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
110
E4DA
The figures in small circles indicate
terminal numbers.
Connections
Terminals 1 and 2 are intentionally shorted. To use an external gate input, connect an external switching device (NPN output sensor or
no-voltage contact switch) to terminals 1 and 2.
Precautions
Avoid mutual interference by placing sensors side by side,
more than 5 mm apart. Mutual interference occur when the
object is inclined or when sensors are mounted opposite one
another.
Do not use the sensor in the following environmental
conditions that adversely affect the sound wave transmission
through the air.
• Locations subject to air convection
• Locations with temperature differences within the sensing
• Rapid change in air flow within the operating range of the
• Use of a transceiver near the sensor
area
sensor
OUTPUT CIRCUIT DIAGRAM
INSTALLATION AND MAINTENANCE
PRECAUTIONS
12 to 24 VDC
4 to 20 mA
0 V
External gate input
15 mA max.,
12 to 24 VDC
12 to 24 VDC
0 V
Ultrasonic sensors may not be capable of detecting sound-
absorbent materials, including: cotton, powders, foam, froth,
soft porous materials, and so forth.
Condensation or drops of water on the vibrator surface of the
ultrasonic sensor may decrease detecting distance.
A 10-minute warm-up period is required from power-up to
allow the linear output to stabilize.
Clean dust off the vibrator surface of the sensor using a blast
of air or a cotton swab. Do not apply pressure on the vibrator
surface.
Alarm
(0 V)
Low
(0 V)
Pass
(0 V)
High
(0 V)
HIGH output
80 mA, 30 VDC max.
Linear output
4 to 20 mA, load impedance 300
Alarm output
80 mA, 30 VDC max.
PASS output
80 mA, 30 VDC max.
LOW output
80 mA, 30 VDC max.
High (+ V)
Pass (+V)
Low (+V)
Alarm (+V)
E4DA
max.