Page 1
... The linear output of the sensor is locked between 21 when the target is outside the measurement range. There is no linear output when the target measurement distance is less than 26 mm. E4DA E4DA Output 80 mA, 30 VDC Part number E4DA-LS7 Part number E4DA-WL1C Part number E39-L52 E49-DD5 101 ...
Page 2
E4DA Specifications SENSOR E4DA-LS7 Method of detection Sensing distance Minimum detectable object Resolution Differential travel Directional angle Variation due to temperature changes Variation due to voltage changes Indicators Materials Mounting Connections Weight Enclosure UL ratings NEMA IEC 144 Approvals UL ...
Page 3
E4DA Nomenclature SENSOR AND AMPLIFIER Shorting wire to disable external gate input To use external gate input, connect a contact or NPN input device with 15 mA, 24 VDC max. switching capacity. Sensing indicator lights when receiving reflected sonic beam ...
Page 4
E4DA Operation FUNCTIONS — AMPLIFIER Classification Function Linear output An analog signal will be output from amplifier terminals 2 and 8 according to the distance measured to a target within the measurement ...
Page 5
E4DA THREE-STAGE CONTROL OUTPUT The two variable distance adjusters on the amplifier front panel are used to establish three control output stages from the input signal. Each four-turn adjuster allows fine tuning of the setting. The ...
Page 6
E4DA INPUT HOLD FUNCTION When the detected object tilts or when it has a rough surface that absorbs the ultrasonic beam, the E4DA sensor may judge that there is no detected object or the signal has not been returned, causing ...
Page 7
... SENSOR E4DA-LS7 16.9 (0.67) 13.2 (0.52) 48 (1.89) 28.5 (1.12) 1.2 (0.05) OPTIONAL EXTENSION CABLE E49-DD5 5 (0.20) dia. 67.4 (2.65) 21.8 (0.86) 6.2 (.24) 13 (0.51) 9.6 (0.38) 20 (0.79) 46.9 12.7 (0.50) (1.85) 10.5 (0.41) 15 (0.59) dia. ...
Page 8
E4DA Engineering Data LINEAR OUTPUT VS. SENSING DISTANCE Measurement range Sensing distance (mm) MINIMUM DETECTABLE OBJECT The size of the minimum detected object depends on whether or not a background object ...
Page 9
E4DA DIRECTIONAL ANGLE vs. OPERATING DISTANCE INFLUENCE OF TEMPERATURE VARIATION The influence of temperature variation depends on the detecting distance. Sensor and Amplifier at the Same Temperature DETECTING ROUND OBJECTS Use the layout below to detect round objects when a ...
Page 10
E4DA OUTPUT CIRCUIT DIAGRAM The figures in small circles indicate terminal numbers VDC External gate input 15 mA max VDC Connections Terminals 1 and 2 are intentionally shorted. To use an external gate input, ...
Page 11
... One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. GC MSEN4 04/01 OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci Specifications subject to change without notice. E4DA OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 111 Printed in the U.S.A. ...