EP3C5E144I7N Altera, EP3C5E144I7N Datasheet - Page 3

IC CYCLONE III FPGA 5K 144 EQFP

EP3C5E144I7N

Manufacturer Part Number
EP3C5E144I7N
Description
IC CYCLONE III FPGA 5K 144 EQFP
Manufacturer
Altera
Series
Cyclone® IIIr

Specifications of EP3C5E144I7N

Number Of Logic Elements/cells
5136
Number Of Labs/clbs
321
Total Ram Bits
423936
Number Of I /o
94
Voltage - Supply
1.15 V ~ 1.25 V
Mounting Type
Surface Mount
Operating Temperature
-40°C ~ 100°C
Package / Case
144-EQFP
Family Name
Cyclone III
Number Of Logic Blocks/elements
5136
# I/os (max)
94
Frequency (max)
437.5MHz
Process Technology
65nm
Operating Supply Voltage (typ)
1.2V
Logic Cells
5136
Ram Bits
423936
Operating Supply Voltage (min)
1.15V
Operating Supply Voltage (max)
1.25V
Operating Temp Range
-40C to 100C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
144
Package Type
EQFP
For Use With
544-2601 - KIT DEV CYCLONE III LS EP3CLS200544-2411 - KIT DEV NIOS II CYCLONE III ED.
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Number Of Gates
-
Lead Free Status / Rohs Status
Compliant
Other names
544-2557

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP3C5E144I7N
Manufacturer:
Altera
Quantity:
135
Part Number:
EP3C5E144I7N
Manufacturer:
ALTERA32
Quantity:
345
Part Number:
EP3C5E144I7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP3C5E144I7N
Manufacturer:
ALTERA
Quantity:
100
Part Number:
EP3C5E144I7N
Manufacturer:
ALTERA
0
Part Number:
EP3C5E144I7N
Manufacturer:
ALTERA/阿尔特拉
Quantity:
20 000
Chapter 1: Cyclone III Device Data Sheet
Electrical Characteristics
© January 2010 Altera Corporation
Table 1–2. Cyclone III Devices Maximum Allowed Overshoot During Transitions over a 10-Year Time
Frame
Note to
(1)
Symbol
V
Figure 1–1
voltage is shown in red and is present on the input pin of the Cyclone III device at over 4.1 V but below 4.2 V. From
Table
a 10-year period. Percentage of high time is calculated as ([delta T]/T) × 100. This 10-year period assumes the
device is always turned on with 100% I/O toggle rate and 50% duty cycle signal. For lower I/O toggle rates and
situations in which the device is in an idle state, lifetimes are increased.
i
Table
(Note 1)
1–1, for an overshoot of 4.1 V, the percentage of high time for the overshoot can be as high as 31.97% over
1–2:
Parameter
shows the methodology to determine the overshoot duration. In the example in
AC Input
Voltage
V
V
V
V
V
V
V
V
V
V
V
V
V
Condition
V
I
I
I
I
I
I
I
I
I
I
I
I
I
I
= 3.95 V
= 4.05 V
= 4.10 V
= 4.15 V
= 4.20 V
= 4.25 V
= 4.30 V
= 4.35 V
= 4.40 V
= 4.45 V
= 4.50 V
= 4.60 V
= 4.70 V
= 4.0 V
Overshoot Duration as % of High Time
95.67
55.24
31.97
18.52
10.74
0.047
Cyclone III Device Handbook, Volume 2
6.23
3.62
1.22
0.71
0.41
0.14
100
2.1
Figure
1–1, overshoot
Unit
%
%
%
%
%
%
%
%
%
%
%
%
%
%
1–3

Related parts for EP3C5E144I7N