CE JMK316 BJ106KD-T Taiyo Yuden, CE JMK316 BJ106KD-T Datasheet - Page 25

no-image

CE JMK316 BJ106KD-T

Manufacturer Part Number
CE JMK316 BJ106KD-T
Description
Cap Ceramic 10uF 6.3VDC X5R 10% SMD 1206 T/R
Manufacturer
Taiyo Yuden
Type
Flatr
Datasheet

Specifications of CE JMK316 BJ106KD-T

Package/case
1206
Mounting
Surface Mount
Capacitance Value
10 uF
Dielectric
X5R
Tolerance
10 %
Voltage
6.3 Vdc
Product Length
3.2 mm
Product Height
0.85 mm
Product Depth
1.6 mm
【Test Methods and Remarks】
【Test Methods and Remarks】
【Test Methods and Remarks】
【Test Methods and Remarks】
* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
mlcc05_reli_e-01
12. Temperature Cycle ( Thermal Shock)
Specified Value
13. Humidity (Steady state)
Specified Value
14. Humidity Loading
Specified Value
15. High Temperature Loading
Specified Value
Note1
Conditions for 1 cycle/ Step 1: Minimum operating temperature
Number of cycles: 5 times
Measurement shall be conducted : 24±2hrs under the standard condition
Temperature:40±2℃
Humidity:90 to 95% RH
Duration:500
Measurement shall be conducted : 24 ±2hrs under the standard condition
According to JIS C 5102 clause 9.9.
Temperature:40±2℃ Humidity:90 to 95% RH
Duration:500
Applied voltage: Rated voltage
Charge/discharge current:50mA max
Measurement shall be conducted : 24 ±2hrs under the standard condition
According to JIS C 5102 clause 9.10.
Temperature:125±3℃
Duration:1000
Applied voltage: Rated voltage x 2
Charge/discharge current:50mA max
Measurement shall be conducted : 24 ±2hrs under the standard condition
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) or CD catalogs.
RELIABILITY DATA
Standard condition: Temperature: 5 to 35℃, Relative humidity: 45 to 85 % RH, Air pressure: 86 to 106kPa
+24
-0
+24
-0
+48
-0
hrs
hrs
hrs
Step 2: Normal temperature
Step 3: Maximum operating temperature
Step 4: Normal temperature
When there are questions concerning measurement results, in order to provide correlation data, the test shall be conducted under the following condition.
Temperature: 20±2℃,
Unless otherwise specified, all the tests are conducted under the "standard condition".
Relative humidity: 60 to 70 % RH, Air pressure: 86 to 106kPa
Appearance: No abnormality
Capacitance change: ±2.5% max
Dissipation factor : Initial value
Insulation resistance: Initial value
Withstanding voltage (between terminals) : No abnormality
Appearance: No abnormality
Capacitance change: ±5% max
Dissipation factor : 0.5% max
Insulation resistance 50MΩ μF or 1000MΩ, whichever is smaller
Appearance: No abnormality
Capacitance change: ±7.5% max
Dissipation factor : 0.5% max
Insulation resistance: 25MΩ μF or 500MΩ, whichever is smaller
Appearance: No abnormality
Capacitance change: ±3% max
Dissipation factor : 0.35% max
Insulation resistance: 50MΩ μF or 1000MΩ, whichever is smaller
+0
-3
+0
-3
℃ 30±3 min.
℃ 30±3 min.
2 to 3 min.
2 to 3 min.
Note1
Note1
Note1
Note1
1 1
mlcc05_reli-R2

Related parts for CE JMK316 BJ106KD-T