PEF80902HV11XT Lantiq, PEF80902HV11XT Datasheet - Page 48

no-image

PEF80902HV11XT

Manufacturer Part Number
PEF80902HV11XT
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEF80902HV11XT

Lead Free Status / Rohs Status
Compliant
G4 wait for DR
Final state after a deactivation request. The S-transceiver remains in this state until DC
is issued.
Unconditional States
Test Mode TM1
Send Single Pulses
Test Mode TM2
Send Continuous Pulses
C/I Commands
Command
Deactivation Request DR
Reset
Send Single Pulses
Send Continuous
Pulses
Receiver not
Synchronous
Activation Request
Activation Request
Loop
Activation Indication
Data Sheet
Abbr.
RES
TM1
TM2
RSY
AR
ARL
AI
Code
0000
0010
0011
0100
1000
1010
0001
1100
Remark
Deactivation Request. Initiates a complete
deactivation by transmitting INFO 0.
Reset of state machine. Transmission of
Info0. No reaction to incoming infos. RES is
an unconditional command.
Send Single Pulses.
Send Continuous Pulses.
Receiver is not synchronous
Activation Request. This command is used to
start an activation.
Activation request loop. The transceiver is
requested to operate an analog loop-back
close to the S/T-interface.
i.e. activation completed.
Activation Indication. Synchronous receiver,
40
Functional Description
PEF 80902
2001-11-12

Related parts for PEF80902HV11XT