PEF80902HV11XT Lantiq, PEF80902HV11XT Datasheet - Page 32

no-image

PEF80902HV11XT

Manufacturer Part Number
PEF80902HV11XT
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEF80902HV11XT

Lead Free Status / Rohs Status
Compliant
The state machines are designed to cope with all ISDN devices with IOM
interfaces. Undefined situations are excluded. In any case, the involved devices will
enter defined conditions as soon as the line is deactivated.
2.3.7.2
For the awake process two signals are defined’ U1W’ and ’U2W’. Depending on the call
direction (up-, downstream) U1W and U2W are interpreted as awake or acknowledge
signals (see figures below).
Figure 6
Figure 7
Data Sheet
Awake Protocol
NT
LT
NT
LT
Awake Procedure initiated by the LT
Awake Procedure initiated by the NT
INFO U2W
2.133 ms
INFO U1W
2.133 ms
6 ms
INFO U1W
2.133 ms
INFO U2W
2.133 ms
12 ms
7 ms
13 ms
7 ms
24
13 ms
INFO U2 (A)
INFO U2 (A)
INFO U1A
Functional Description
INFO U1A
ITD06385.vsd
ITD06386.v sd
®
PEF 80902
-2 standard
2001-11-12

Related parts for PEF80902HV11XT