AD5724RBREZ Analog Devices Inc, AD5724RBREZ Datasheet - Page 28

no-image

AD5724RBREZ

Manufacturer Part Number
AD5724RBREZ
Description
IC DAC 12BIT DSP/SRL 24TSSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD5724RBREZ

Data Interface
Serial
Design Resources
Software Configurable 12-Bit Quad Channel Unipolar/Bipolar Voltage Output Using AD5724R (CN0085)
Settling Time
10µs
Number Of Bits
12
Number Of Converters
4
Voltage Supply Source
Analog and Digital, Dual ±
Power Dissipation (max)
310mW
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-TSSOP Exposed Pad, 24-eTSSOP, 24-HTSSOP
Resolution (bits)
12bit
Sampling Rate
1.1MSPS
Input Channel Type
Serial
Supply Voltage Range - Digital
2.7V To 5.5V
Supply Current
2.5mA
Digital Ic Case Style
TSSOP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD5724RBREZ
Manufacturer:
Analog Devices Inc
Quantity:
135
Part Number:
AD5724RBREZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
AD5724RBREZ
Quantity:
1 000
Part Number:
AD5724RBREZ-REEL7
Manufacturer:
ANALOG
Quantity:
20 000
AD5724R/AD5734R/AD5754R
CONTROL REGISTER
The control register is addressed by setting the three REG bits to 011. The value written to the address and data bits determines the
control function selected. The control register options are shown in Table 24 and Table 25.
Table 24. Programming the Control Register
MSB
R/ W
0
0
0
0
Table 25. Control Register Functions
Option
NOP
Clear
Load
SDO disable
CLR select
Clamp enable
TSD enable
Table 26. CLR Select Options
CLR Select Setting
0
1
Zero
0
0
0
0
REG2
0
0
0
0
No operation instruction used in readback operations.
Description
Addressing this function sets the DAC registers to the clear code and updates the outputs.
Addressing this function updates the DAC registers and, consequently, the DAC outputs.
Set by the user to disable the SDO output. Cleared by the user to enable the SDO output (default).
See Table 26 for a description of the CLR select operation.
Set by the user to enable the current limit clamp (default). The channel does not power down on detection of
overcurrent; the current is clamped at 20 mA.
Cleared by the user to disable the current-limit clamp. The channel powers down on detection of overcurrent.
Set by the user to enable the thermal shutdown feature. Cleared by the user to disable the thermal shutdown
feature (default).
REG1
1
1
1
1
Unipolar Output Range
0 V
Midscale
REG0
1
1
1
1
A2
0
0
1
1
A1
0
0
0
0
A0
0
1
0
1
DB15 to DB4
Don’t care
Rev. C | Page 28 of 32
Output CLR Value
DB3
TSD enable
Bipolar Output Range
0 V
Negative full scale
Clear, data = don’t care
Load, data = don’t care
NOP, data = don’t care
DB2
Clamp enable
DB1
CLR select
LSB
DB0
SDO disable

Related parts for AD5724RBREZ