1408312-1 TE Connectivity, 1408312-1 Datasheet - Page 6

no-image

1408312-1

Manufacturer Part Number
1408312-1
Description
RF/COAXIAL, MMCX PLUG, 50OHM, CRIMP/SLDR
Manufacturer
TE Connectivity
Datasheets

Specifications of 1408312-1

Connector Type
MMCX Coaxial
Body Style
Straight Plug
Coaxial Termination
Solder / Crimp
Impedance
50ohm
Rg Cable Type
RG-316
Connector Mounting
Cable
Rohs Compliant
Yes
Connector Impedance (?)
50
Cable Diameter (max.) (mm [in])
2.25 [0.089]
Assembly Instruction
MV4
Connector Style
Plug
Coaxial Cable Type
RG 316
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Applies To
Coaxial Cable
Packaging Quantity
100
4.
4.1.
4.2.
4.3.
4.4.
Rev B
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form , fit or function are m ade to the product or m anufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determ ined by developm ent/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that the product m eets the requirem ents of Figure 1. Failures
attributed to equipm ent, test setup or operator deficiencies shall not disqualify the product. If product
failure occurs, corrective action shall be taken and specim ens resubm itted for qualification. Testing to
confirm corrective action is required before resubm ittal.
Quality Conform ance Inspection
The applicable quality inspection plan shall specify the sam pling acceptable quality level to be used.
Dim ensional and functional requirem ents shall be in accordance with the applicable product drawing
and this specification.
Specim en Selection
Specim ens shall be prepared in accordance with applicable Instruction Sheets and shall be
selected at random from current production. Test group 1 shall consist of 21 specim ens. Test
groups 2, 3, 4, 5, 6, 7 and 8 shall consist of 3 specim ens each.
Test Sequence
Qualification inspection shall be verified by testing specim ens as specified in Figure 2.
108-2084
6 of 6

Related parts for 1408312-1