1274584-1 TE Connectivity, 1274584-1 Datasheet - Page 5

RF/COAXIAL BNC BHD PLUG R/A 75OHM SOLDER

1274584-1

Manufacturer Part Number
1274584-1
Description
RF/COAXIAL BNC BHD PLUG R/A 75OHM SOLDER
Manufacturer
TE Connectivity
Datasheets

Specifications of 1274584-1

Connector Type
BNC Coaxial
Body Style
Right Angle Bulkhead Plug
Coaxial Termination
Solder
Impedance
75ohm
Contact Material
Phosphor Bronze
Contact Plating
Gold
Frequency Max
2GHz
Rohs Compliant
Yes
Product Type
Connector - RF
Gender
Jack
Stacked
No
Pcb Mounting Orientation
Right Angle
Grade
Commercial
Pcb Mount Retention
Without
Body Material
Brass
Sealed
No
Isolated
No
Dielectric Material
PTFE
Number Of Ports
1
Solder Terminal
With
Surface Mountable
No
Panel Mount Retention
With
Panel Mount Retention Type
Bulkhead
Panel Attachment Style
Rear Mount
Connector Impedance (?)
75
Insulation Resistance (m?)
1,000
Frequency
DC - 2 GHz
Pcb Height (mm [in])
8.53 [0.336]
Hardware Included
No
Body Plating
Nickel
Polarized
No
Pcb Tail Length (mm [in])
4.00 [0.157]
Center Contact Material
Phosphor Bronze
Center Contact Plating
Gold
Connector Style
Jack
Government/industry Qualification
No
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Wave solder capable to 240°C, Wave solder capable to 260°C, Wave solder capable to 265°C, Reflow solder capable to 245°C, Reflow solder capable to 260°C, Pin-in-Paste capable to 245°C, Pin-in-Paste capable to 260°C
Rohs/elv Compliance History
Always was RoHS compliant
Applies To
Printed Circuit Board
For Use With
Mini BNC Connector
4.
4.1.
4.2.
4.3.
4.4.
Rev C
QUALITY ASSURANCE PROVISIONS
Qualification Testing
A.
B.
Requalification Testing
If changes significantly affecting form , fit or function are m ade to the product or m anufacturing process,
product assurance shall coordinate requalification testing, consisting of all or part of the original testing
sequence as determ ined by developm ent/product, quality and reliability engineering.
Acceptance
Acceptance is based on verification that the product m eets the requirem ents of Figure 1. Failures
attributed to equipm ent, test setup or operator deficiencies shall not disqualify the product. If product
failure occurs, corrective action shall be taken and specim ens resubm itted for qualification. Testing to
confirm corrective action is required before resubm ittal.
Quality Conform ance Inspection
The applicable quality inspection plan shall specify the sam pling acceptable quality level to be used.
Dim ensional and functional requirem ents shall be in accordance with the applicable product drawing
and this specification.
Specim en Selection
Specim ens shall be prepared in accordance with applicable Instruction Sheets and shall be
selected at random from current production. Each test group shall consist of a m inim um of 5
specim ens.
Test Sequence
Qualification inspection shall be verified by testing specim ens as specified in Figure 2.
Low Level Contact Resistance Measurem ent Points
Figure 3
108-2159
5 of 5

Related parts for 1274584-1